Findings - PZ - 2001 - PP-5-01 - Pp Approval For Autumcrest Subd/39.92 Acre/20-Lot ORIGINAL BEFORE THE EAGLE PLANNING AND ZONING COMMISSION IN THE MATTER OF AN APPLICATION FOR A PRELIMINARY PLAT FOR AUTUMNCREST SUBDIVISION FOR PACIFIC RIDGE ) ) ) FINDINGS OF FACT AND CONCLUSIONS OF LAW CASE NUMBER PP-5-0l The above-entitled preliminary plat application came before the Eagle Planning and Zoning Commission for their recommendation on September 10, 2001. The Eagle Planning and Zoning Commission having heard and taken oral and written testimony, and having duly considered the matter, makes the following Findings of Fact and Conclusions of Law; FINDINGS OF FACT: A. PROJECT SUMMARY: Pacific Ridge, represented by David Bailey with Hubble Engineering Inc., is requesting preliminary plat approval for Autumncrest Subdivision. The 39.92-acre, 20-lot (19- buildable) residential subdivision is generally located on the west side of Ballantyne Road, approximately 114 mile south of Beacon Light Road. B. APPLICATION SUBMITTAL: The application for this item was received by the City of Eagle on May 31, 2001. e. NOTICE OF PUBLIC HEARING: Notice of Public Hearing on the application for the Eagle Planning and Zoning Commission was published in accordance for requirements of Title 67, Chapter 6S, Idaho Code and the Eagle City ordinances on July 21, 2001. Notice of this public hearing was mailed to property owners within three-hundred feet (300-feet) of the subject property in accordance with the requirements of Title 67, Chapter 6S, Idaho Code and Eagle City Code on July 18,2001. Requests for agencies' reviews were transmitted on June 1,2001, in accordance with the requirements of the Eagle City Code. D. illS TORY OF RELEVANT PREVIOUS ACTIONS: (None) E. COMPANION APPLICATIONS: A-2-01 & RZ-S-Ol [Rezone upon Annexation from RUT- (Ada County designation) to R-E -- Residential Estates - (up to one unit per 2-acres maximum)] & ZOA-4-01 (Zoning Ordinance Amendment to exempt lots with street side frontage located within zoning districts A, A-R, R-E and R-l from the required minimum lO-percent increase in lot area as referenced in ECC 8-2-4 (H». Page 1 of 15 K:\Planning Dept\Eagle Applications\SUBS\200 1 \Autumncrest pzf.doc F. COMPREHENSIVE PLAN LAND USE MAP AND ZONING MAP DESIGNATIONS: COMP PLAN ZONING LAND USE DESIGNA TlON DESIGNA TION Existing Residential Estates (I-unit RUT (Residential) Residence/Agriculture per 2-acres maximum) Proposed No Change R-E (Residential) Residential Subdivision North of site Residential Estates (I-unit RUT (Residential) Residential per 2-acres maximum) South of site Residential Estates (I-unit R-E (Residential) Tahoe Ridge Residential per 2-acres maximum) Subdivision East of site Residential Estates (I-unit R-E (Residential) Residential per 2-acres maximum) West of site Residential Estates (I-unit RUT (Residential) Residential per 2-acres maximum) G. DESIGN REVIEW OVERLAY DISTRICT: Not in the DDA, TDA or CEDA. H. SITE DATA: Total Acreage of Site - 39.92 Total Number of Lots - 20 Residential - 20 Commercial - 0 Industrial - 0 Common - 0 Total Number of Units- Single-family - 19 Duplex - 0 Multi-family - 0 Total Acreage of Any Out-Parcels - none Page 2 of IS K:\Planning Dept\Eagle Applications\SUBS\2001\Autumncrest pzf.doc - - ---------------------------------- ADDITIONAL SITE DATA PROPOSED REQUIRED Dwelling Units Per Gross Acre 0.47-units per acre I-unit per 2-acre maximum Minimum Lot Size 73,6O3-square feet (l.69-acres) 78,408 S.F. (1.8-acres) Minimum Lot Width 198-feet (approx.) 1O0-feet Minimum Street Frontage 38-feet (approx.) 35-feet Total Acreage of Common Area 1.0 I-acres O-acres Percent of Site as Common Area 0.25% 0% I. GENERAL SITE DESIGN FEATURES: Greenbelt Areas and Landscape Screening: Eagle City Code Section 8-2A-7 (J)(4)(a) requires a minimum 35-foot wide landscape buffer area between urban or rural collectors and new residential developments. Berming, fencing and landscaping details are required for Design Review Board review and approval prior to City approval of a final plat Open Space: Will provide a total of .25% common area within the interior of the subdivision. 0% common area is required for this zoning district. Storm Drainage and Flood Control: Specific drainage system plans are to be submitted to the City Engineer for review and approval prior to the City Engineer signing the final plat. The plans are to show how swales, or drain piping, will be developed in the drainage easements. Also, the CC&R' s are to contain clauses to be reviewed and approved by the City Engineer and City Attorney, requiring that lots be so graded that all runoff runs either over the curb, or to the drainage easement, and that no runoff shall cross any lot line onto another lot except within a drainage easement. Utility and Drainage Easements, and Underground Utilities: Eagle City Code section 9-3-6 requires utility easements to be not less than 12-feet wide. Fire Hydrants and Water Mains: Hydrants are to be located and installed as may be required by the Eagle Fire District. On-site Septic System (yes or no) - yes Preservation of Existing Natural Features: There are numerous existing trees located on this site. Eagle City Code Section 9-3-8 (B) states that existing natural features which add value to residential development and enhance the attractiveness of the community (such as trees, watercourses, historic spots and similar irreplaceable assets) shall be preserved in the design of the subdivision. Page 3 of 15 K:\Planning Dept\Eagle Applications\SUBS\2001\Autumncrest pzf.doc Preservation of Existing Historical Assets: Staff is not aware of any existing historical assets on the site which would be required to be preserved. If during excavation or development of the site, any historical artifacts are discovered, state law requires immediate notification to the state. J. STREET DESIGN: Private or Public Streets: Public The applicant is proposing to construct all internal roadways as 33-foot street sections with concrete shoulders and abutting borrow ditches within SO-feet of right-of-way. Applicant's Justification for Private Streets (if proposed): None proposed Blocks Less Than SOO': None Cul-de-sac Design: One cul-de-sac is proposed to be constructed 480-feet in length and terminate within a radius of SO-feet of right-of-way. Curbs, Gutters and Sidewalks: Curbs and gutters are not proposed, however, a one foot wide concrete ribbon curb and a four-foot wide striped non-motorized travel lane, which meets Ada County Highway District standards, is required for both sides of the interior streets. Lighting: Lighting for the proposed public streets is required. Location and lighting specifications shall be provided to the City Zoning Administrator prior to the City Engineer signing the final plat. Street Names: Street name approval by the Ada County Street Names Committee has not been received to date. Approval from that committee is required prior to final plat approval. K. ON AND OFF-SITE PEDESTRIANIBICYCLE CIRCULA nON: Pedestrian Walkways: Striped bike and pedestrian walkways are required by the Ada County Highway District within the subdivision. Bike Paths: Eagle City Code section 9-4-1-7 states that a bicycle path way shall be provided in all subdivisions as part of the public right-of-way or separate easement, as may be specified by the City Council. L. PUBLIC USES PROPOSED: None M. PUBLIC USES SHOWN ON FUTURE ACQUISITIONS MAP: No map currently exists N. SPECIAL ON-SITE FEATURES: Page 4 of 15 K:\Planning Dept\Eagle Applications\SUBS\2001\Autumncrest pzf.doc "- "- -"""-"- ---"-"-"--"--"---" Areas of Critical Environmental Concern - no Evidence of Erosion - no Fish Habitat - no Floodplain-no Mature Trees - yes Riparian Vegetation - no Steep Slopes - no Stream/Creek - existing ditch to be tiled Unique Animal Life - unknown Unique Plant Life - unknown Unstable Soils - unknown Wildlife - unknown O. SUMMARY OF REVIEW OF ENVIRONMENTAL ASSESSMENT PLAN (IF REQUIRED): A complete environmental plan is not required. P. AGENCY RESPONSES: The following agencies have responded and their correspondence is attached. Comments, which appear to be of special concern, are noted below: City Engineer: All comments within the Engineer's letter dated July 24, 2001 are of special concern (see attached). Ada County Highway District Central District Health Department of Environmental Quality Eagle Fire Department Eagle Sewer District Farmer's Union Ditch Company New Union Ditch Company Q. LETTERS FROM THE PUBLIC: Letter from Lisa Szentes, 2593 W. Brockton Court, date stamped July 30,2001. STAFF ANALYSIS: A. COMPREHENSIVE PLAN PROVISIONS, WHICH ARE OF SPECIAL CONCERN REGARDING THIS PROPOSAL: . The Comprehensive Plan Land Use Map designates this site as "Residential Estates", suitable primarily for single-family residential development on acreages that may be in transition from agricultural to residential use or may combine small-scale agricultural uses with residential uses. Residential density of up to one dwelling unit per two gross acres may be considered by the City for this area. B. ZONING ORDINANCE PROVISIONS, WillCH ARE OF SPECIAL CONCERN REGARDING TillS PROPOSAL: . Section 8-2-4 (H) states that all lots with street side frontage shall have a minimum Page 5 of 15 K:\Planning Dept\Eagle Applications\SUBS\200 1 \Autumncrest pzf.doc ----------..- .-. ._-~ --- - ---- lot area that is 10 percent larger than shown in the table. . Section 8-2A-7 (J)(4)(a) Major Roadways: New residential developments, including, but not limited to, subdivisions and multi-family developments, shall be buffered from streets classified as collectors, arterials, freeways, or expressways, to protect residential communities from noisy, potentially dangerous, high-speed roads. The buffer area shall be defined as the distance from the outside wall of the lowest story of any single-family attached or detached dwelling and the right-of-way line of the roadway. The lowest story must be screened from the view of any street classified as a collector, arterial, freeway, or expressway. This buffer is required either on individual lots or as an easement, or as part of the common open space owned and maintained by a homeowners' association. Any landscaping proposed to be within the public right of way shall not be included as a part of the buffer area required below. The height for berrning/fencing, as noted below, shall be measured from the elevation of the final grade of the adjacent roadway (measured at the centerline) to the top of the proposed berming/fencing. The required buffer area width, plantings, and fencing are as follows: Any road designated as an urban or rural collector on the AP A Functional Street Classification Map: A minimum of thirty five feet (3S') wide buffer area (not including right of way) shall be provided with the following plants per one hundred (100) linear feet of right of way: four (4) shade trees, five (S) evergreen trees, and twenty four (24) shrubs. Each required shade tree may be substituted with two (2) flowering/ornamental trees, provided that not more than fifty percent (SO%) ofthe shade trees are substituted. A minimum five foot (S') high, maximum eight foot (8') high, berm, panelized vinyl fence, decorative block wall, or cultured stone, decorative rock, or similarly designed concrete wall, or combination thereof shall be provided within the buffer area. The maximum slope for any berm shall be three feet (3') horizontal distance to one-foot (1 ') vertical distance. If a panelized vinyl fence, decorative block wall, or cultured stone, decorative rock, or similarly designed concrete wall is to be provided, in combination with the berm, a four foot (4') wide flat area at the top of the berm shall be provided for the placement of the fence or decorative block wall. Panelized vinyl fencing shall be no higher than four feet (4'). Chain link, cedar, and similar high maintenance and/or unsightly fencing shall not be permitted. The five foot (S') minimum height requirement for the berming/fencing shall be permitted to be decreased one foot (1') for every thirteen feet (13') of additional buffer area added to the thirty five foot (3S') wide buffer noted above. e. SUBDIVISION ORDINANCE PROVISIONS wmCH ARE OF SPECIAL CONCERN REGARDING TillS PROPOSAL: . Section 9-4-1-6 A Sidewalks shall be required on both sides of the street; except, that where the average width of lots, as measured at the street frontage line or at the building setback line, is over one hundred feet (100'), sidewalks on only one side of the Page 6 of IS K:\Planning Dept\Eagle Applications\SUBS\2001\Autumncrest pzf.doc street may be allowed. . Section 9-4-1-9 C (1) Pressurized Irrigation Facilities: For any new subdivision and/or PUD, to be provided with a public water system and containing more than four (4) lots, all residential dwelling units within such subdivision shall be provided with a pressurized irrigation system to be served with irrigation water unless a waiver, as outlined herein, is approved by the City Council. D. DISCUSSION: . The Comprehensive Plan Land Use Map designates this site as Residential Estates (one- unit per two-acres maximum). The applicant is proposing .47-units per acre. . The applicant should provide a landscape plan showing berming, fencing, and planting details within the required 35-foot wide buffer area along Ballantyne Road abutting this site for review and approval by the Design Review Board prior to City approval of a final plat. . The proposed Lot 5, Block 1 (located in the northwest comer of this parcel) is noted on the preliminary plat as a non-buildable lot. The applicant intends to either sell the proposed Lot 5 to the property directly to the north (located in Kensington Meadows Subdivision) or, if this land transaction fails to occur, Lot S will be incorporated into the abutting Lots 4 and 6, Block 1. This preliminary plat proposes to create a non-conforming lot because Lot 5 (1.69-acres) does not meet the minimum lot size requirement of 1.8- acres. In addition, the preliminary plat proposes to create Lot 5 as a piece of land that is "land-locked", that is; no access to a public right-of-way is provided. A property boundary (lot line) adjustment should have occurred prior to the submittal of an application for a preliminary plat if the applicant desired to sell the parcel to an abutting property owner. Staff believes that a preliminary plat cannot be approved with a lot that is "landlocked" and does not meet minimum area requirements, thereby creating a non- conforming lot. Therefore, the applicant should provide a revised preliminary plat that either incorporates Lot 5 into the abutting lots within this subdivision or reconfigure the lot to provide both an area that meets the minimum required lot size and provides access to the public right-of- way. . Two proposed lots (Lots 9 and 10, Block 2) are approximately two-feet smaller than the required minimum lot size within an R-E zoning district. The applicant should provide a revised preliminary plat which shows these two lots (as well as all lots within the subdivision) as meeting the required minimum lot size of 78, 408 square-feet (1.8-acres). . Eagle City Code requires that all lots with street side frontage shall have a lot size that is a minimum of ten-percent larger than the minimum required within the applicable zoning district. In this instance, the minimum lot size for the proposed "comer lots" would need to be 86,249 square-feet. The proposed ordinance amendment ZOA-4-01, if approved, would exclude lots within an R-E zone from having to meet this aforementioned Page 7 of IS K:\Planning Dept\Eagle Applications\SUBS\2001\Autumncrest pzf.doc requirement. Therefore, the applicant should provide a revised preliminary plat that shows all lots with street side frontage to be a minimum of 86,249 square-feet unless the proposed zoning ordinance amendment ZOA-4-01 is approved by the City Council. . The applicant has not provided a pressurized irrigation plan as required by Eagle City Code. The applicant should provide a plan delineating the pressurized irrigation prior to City approval of the final plat. . The Ada County Highway District in its Commission report dated June 28,2001 prohibits any direct parcel or lot access to Ballantyne Road. Lot 3, Block 2 is proposed to access Ballantyne Road directly rather than through the subdivision. Therefore, the applicant should revise the plat to provide access to Lot 3, Block 2, through the internal roadway system of the subdivision rather than directly to Ballantyne Road. . In previous action, the City Council has required that buffer areas should be located within a common lot to be owned and maintained by the homeowner's association, and stated as such on the plat. The applicant should provide a revised preliminary plat that shows the buffer area located within a common lot with a note stating it is to be owned and maintained by the homeowner's association. . Regarding sidewalks for this site, the City Council has previously determined that for subdivisions with I-acre or larger lot sizes, 4-foot wide bike/ pedestrian pathways striped along either edge of the roadway provides adequate room for pedestrian access throughout these types of subdivisions. In addition, ACHD requires that the developer stripe a 4-foot wide section on both sides of the roadway edge for bike/pedestrian use in subdivisions with lot sizes I.S-acres in size or greater. The applicant should be required to submit with the final plat a striping plan showing a 4- foot wide path striped on both edges of all roadways within this site. The plan should include pedestrian designation markings such as diamonds or pedestrian/bicycle symbols to be included with the striped areas. . An un-platted parcel abutting the southwest comer of this proposed subdivision currently accesses public right-of-way via a 2S-foot wide strip of land between the parcel's eastern boundary and Ballantyne Road. The majority of this strip of land is to be purchased and incorporated into the proposed Autumncrest Subdivision, except for the western 300-feet of the strip. This remaining strip is proposed to be widened to SO-feet and will serve as an access to the un-platted parcel from the proposed roadway labeled Yellow Birch A venue. STAFF RECOMMENDATION PROVIDED WITHIN THE STAFF REPORT: Staff recommends approval with the site specific conditions of approval and the standard conditions of approval provided within the staff report. PUBLIC HEARING OF THE COMMISSION: A. A public hearing on the application was held before the Planning and Zoning Commission on September 4, 2001, at which time testimony was taken and the public hearing remained open. The Commission continued this matter until September 10, 2001, received additional testimony, closed the public hearing and made their recommendation at that time. Page 8 of 15 K:\Planning Dept\Eagle Applications\SUBS\2001 \Autumncrest pzf.doc B. Oral testimony in opposition to this proposal was presented to the Planning and Zoning Commission by three (3) individuals with concerns regarding the loss of the "country feel" that 2-acre parcels and higher density will create; incompatibility with existing 5-acre lots surrounding this site; overcrowded schools; water rights and traffic counts. C. Oral testimony in favor of this proposal was presented to the Planning and Zoning Commission by one (1) individual who felt 2-acre parcels are more manageable than 5-acre parcels and that irrigation water is sufficient all year. D. Written testimony in opposition to this proposal was presented to the Planning and Zoning Commission by seven (7) individuals with concerns regarding increased traffic; increased demand on schools and other services; change in rural character and integrity of the City; and the incompatibility of two-acre lots with the existing 5-acre lots surrounding this site. E. A petition signed by fifty-five (55) individuals in opposition to this proposal was presented to the Planning and Zoning Commission. COMMISSION DECISION: The Commission voted 3 to 1 (Bloom against) (Deckers absent) to recommend approval of PP-5- 01 for a preliminary plat for Autumncrest Subdivision for Pacific Ridge with the following staff recommended site specific conditions of approval and standard conditions of approval with text shown with strike-thru to be deleted by the Commission and text shown with underline to be added by the Commission. SITE SPECIFIC CONDITIONS OF APPROVAL: 1. Comply with all requirements within the City Engineer's letter dated July 24,2001. 2. Comply with all requirements of the Ada County Highway District, specifically (but not limited to) roadway design and construction of sidewalks. 3. Construct a 5-foot wide (minimum) meandering concrete sidewalk along Ballantyne Road abutting the site. 4. Revise the preliminary plat to either incorporate Lot 5, Block 1 into the abutting lots within this subdivision or reconfigure the lot to provide a minimum lot area of 1.8-acres and access to the public right-of-way. 5. Revise the preliminary plat to change Lots 9 and 10, Block 2, to measure a minimum of 78,408 square- feet (1.8-acres). 6. Provide a revised preliminary plat that shows all lots with street side frontage to be a minimum of 86,249 square-feet unless the proposed zoning ordinance amendment ZOA-4-01 is approved by the City Council. 7. The applicant shall provide a plan delineating a pressurized irrigation system to serve all lots within the subdivision prior to city approval of the final plat. 8. Revise the coRfiguratioR øf Lot 3, Block 2 to pro'lide access from the iRtemal street system of the Page 9 of IS K:\Planning Dept\Eagle Applications\SUBS\2001\Autumncrest pzf.doc sübdivisioR. Direct lot access to BallantYRe Road is 13rohibited. 9. Provide a revised 13r-eliminary 131at that elimiBates .Nate tt9 to elimiRate the statemeBt that Let 3, Block 2 shall have access to BallaRt)'Re Road. The Rote shall state that RO lot or 13arcel shall have direct aceess ta Ballant)'Be Road, 13ÐrsHant to tHe r-eqüiremeats of the .^.da CoHnty Highway Distriet. 10. All existing buildings located on Lot 3, Block 2 which are situated upon or within 5-feet of the proposed lot lines shall be removed or the lot lines reconfigured to incorporate the buildings, prior to the City Clerk signing the final plat. 11. Provide a revised preliminary plat that changes the width of the easement on plat Note #1 to 12-feet. 12. Revise Note # 11 on the plat to replace the words "Eagle City Council" with the words "Zoning Administrator" in reference to approval of street light location. 13. The applicant shall provide a landscape plan showing berming, fencing, and planting details within the required 35-foot wide buffer area along Ballantyne Road abutting this site for review and approval by the Design Review Board prior to City approval of a final plat. 14. Submit, with the final plat, a striping plan showing a 4-foot wide path striped on both edges of all roadways within this site. The plan shall include pedestrian designation markings such as diamonds or pedestrianlbicycle symbols to be included with the striped areas. 15. Place a note on the plat which states that the 35-foot wide buffer area abutting Ballantyne Road is to be located within a common lot to be owned and maintained by the homeowner's association. Provide a statement in the CC&R's that one homeowners association in perpetuity shall maintain the common lot. 16. Place a note on the final plat which states in general that surrounding land with farm uses and related activities shall be protected pursuant to the Idaho Right to Farm Act. 17. Any stub street which is expected to be extended in the future shall be provided with a sign generally stating that, "This street is to be extended in the future". STANDARD CONDITIONS OF APPROVAL: 1. The applicant shall comply with all requirements of the Ada County Highway District and/or the Idaho Transportation Department, including but not limited to approval of the drainage system, curbs, gutters, streets and sidewalks. 2. Correct street names, as approved by the Ada County Street Name Committee, shall be placed on the plat prior to the City Engineer signing the final plat. 3. Complete water and sewer system construction plans shall be reviewed and approved by the City Engineer. Required improvements shall include, but not be limited to, extending all utilities to the platted property. The developer may submit a letter in lieu of plans explaining why plans may not be necessary. 4. Idaho Department of Health & Welfare approval of the sewer and water facilities is required prior to the City Engineer signing the final plat (1.e. Title 50, Chapter 13 and 1.e. 39-118). Page 10 of 15 K:\Planning Dept\Eagle Applications\SUB S\200 1 \Autumncrest pzf.doc 5. 6. 7. 8. Written approval of all well water for any shared or commercial well shall be obtained from the Idaho Department of Water Resources prior to the City Engineer signing the final plat. Unless septic tanks are permitted, wet line sewers will be required and the applicant will be required to furnish the City Engineer with a letter from the sewer entity serving the property, accepting the project for service, prior to the City Engineer signing the final plat (B.e.e. 9-20-8.4) All homes being constructed with individual septic systems shall have the septic systems placed on the street side of the home or shall have their sewer drainage system designed with a stub at the house front to allow for future connection to a public sewer system. Per Idaho Code, Section 31-380S, concerning irrigation rights, transfer and disclosure, the water rights appurtenant to the lands in said subdivision which are within the irrigation entity will be transferred from said lands by the owner thereof; or the subdivider shall provide for underground tile or other like satisfactory underground conduit to permit the delivery of water to those landowners within the subdivision who are also within the irrigation entity. See Eagle City Code Section 9-4-1-9(C), which provides overriding and additional specific criteria for pressurized irrigation facilities. Plans showing the delivery system must be approved by a registered professional engineer and shall be approved by the City Engineer prior to the City Engineer signing the final plat. 9. The applicant shall submit a letter from the appropriate drainage entity approving the drainage system and/or accepting said drainage; or submit a letter from a registered professional engineer certifying that all drainage shall be retained on-site prior to the City Engineer signing the final plat. A copy of the construction drawing(s) shall be submitted with the letter. 10. Drainage system plans shall be submitted to the City Engineer for review and approval prior to the City Engineer signing the final plat. The plans shall show how swales, or drain piping, will be developed in the drainage easements. The approved drainage system shall be constructed, or a performance bond shall be submitted to the City Clerk, prior to the City Engineer signing the final plat. The CC&R' s shall contain clauses to be reviewed and approved by the City Engineer and City Attorney, prior to the City Engineer signing the final plat, requiring that lots be so graded that all runoff runs either over the curb, or to the drainage easement, and that no runoff shall cross any lot line onto another lot except within a drainage easement. 11. No ditch, pipe or other structure or canal, for irrigation water or irrigation waste water owned by an organized irrigation district, canal company, ditch association, or other irrigation entity, shall be obstructed, routed, covered or changed in any way unless such obstruction, rerouting, covering or changing has flrst been approved in writing by the entity. A Registered Engineer shall certify that any ditch rerouting, piping, covering or otherwise changing the existing irrigation or waste ditch (1) has been made in such a manner that the flow of water will not be impeded or increased beyond carrying capacity of the downstream ditch; (2) will not otherwise injure any person or persons using or interested in such ditch or their property; and (3) satisfied the Idaho Standards for Public Works Construction. A copy of such written approval and certification shall be filed with the construction drawing and submitted to the City Engineer prior to the City Engineer signing the final plat. 12. Street light plans shall be submitted and approved as to the location, height and wattage to the City Page 11 of IS K:\Planning Dept\Eagle Applications\SUBS\200 1 \Autumncrest pzf.doc 13. 14. Engineer prior to the City Engineer signing the final plat. All construction shall comply with the City's specifications and standards. The applicant shall delineate on the face of the final plat an easement, acceptable to the City Engineer, for the purpose of installing and maintaining street light fixtures, conduit and wiring lying outside any dedicated public right-of-way, prior to the City Engineer signing the final plat. The applicant shall pay applicable street light inspection fees on the proposed subdivision prior to signing of the final plat by the Eagle City Engineer. The applicant shall provide utility easements as required by the public utility providing service, and as may be required by the Eagle City Code, prior to the City Engineer signing the final plat. An approval letter from the Eagle Fire Department shall be submitted to the City prior to the City Engineer signing the final plat. The letter shall include the following comments and minimum requirements, and any other items of concern as may be determined by the Eagle Fire Department officials: a. The applicant has made arrangements to comply with all requirements of the Fire Department. The proposed flre hydrant locations shall be reviewed and be approved in writing by the Eagle Fire Department prior to the City Engineer signing the final plat. Minimum flow per hydrant shall be 1,000 gallons per minute for one and two family dwellings, 1,500 gallons per minute for dwellings having a fire area in excess of 3,600 square feet, and I,SOO gallons per minute for non-residential uses (i.e.; Commercial, Industrial, Schools, etc.). Flow rates shall be inspected in accordance with all agencies having jurisdiction, and shall be verified in writing by the Eagle Fire Department prior to issuance of any building permits. The proposed fIfe protection system shall be reviewed and approved by the Eagle Fire Department prior to issuance of a building permit. b. c. d. IS. Covenants, homeowner's association by-laws or other similar deed restrictions, acceptable to the Eagle City Attorney which provide for the use, control and mutual maintenance of all common areas, storage facilities, recreational facilities, street lights or open spaces shall be reviewed by the Eagle City Attorney prior to the City Engineer signing the final plat. A restrictive covenant must be recorded and a note on the face of the final plat is required, providing for mutual maintenance and access easements. Appropriate papers describing decision-making procedures relating to the maintenance of structures, grounds and parking areas shall be reviewed and approved by the Eagle City Attorney prior to the City Engineer signing the final plat. 16. Should the homeowner's association be responsible for the operation and maintenance of the storm drainage facilities, the covenants and restrictions, homeowner's association by-laws or other similar deed restrictions acceptable to the Eagle City Attorney shall be reviewed by the Eagle City Attorney prior to the City Engineer signing the final plat. 17. The applicant shall submit an application for Design Review, and shall obtain approval for all required landscaping, common area and subdivision signage prior to the City Engineer signing the final plat. Page 12 of 15 K:\Planning Dept\Eagle Applications\SUBS\2001\Autumncrest pzf.doc 18. 19. 20. 21. 22. Any recreation area, greenbelt area or pathway area along the Boise River, Dry Creek or any other area designated by the City Councilor Eagle City Pathway/Greenbelt Committee for a path or walkway shall be approved in writing by the Eagle City Pathway/Greenbelt Committee prior to approval of the final plat by the City Council. Conservation, recreation and river access easements (if applicable) shall be approved by the Eagle City Pathway/Greenbelt Committee and shall be shown on the final plat prior to approval of the final plat by the City Council. The applicant shall place a note on the face of the plat which states: "Minimum building setback lines shall be in accordance with the applicable zoning and subdivision regulations at the time of issuance of the building permit or as specifically approved and/or required". The applicant shall comply with the provisions of the Eagle City Code, pertaining to floodplain and river protection regulations (if applicable) prior to the City Engineer signing the final plat. The development shall comply with the Boise River Plan (if applicable) in effect at the time of City Council consideration of the final plat. 23. The applicant shall obtain written approval of the development relative to the effects of the Boise River Flood Plain (if applicable) from the Corps. of Engineers prior to approval of the final plat by the City Engineer. 24. The applicant shall obtain approval of the development relative to its effects on wetlands or other natural waterways (if applicable) from the Corps. of Engineers and the Idaho Department of Water Resources and/or any other agency having jurisdiction prior to the City Engineer signing the final plat. 2S. Basements in homes in the flood plain are prohibited. 26. The Americans with Disabilities Act, Uniform Building Code, Eagle City Code, Eagle Comprehensive Plan, and all applicable County, State and Federal Codes and Regulations shall be complied with. All design and construction shall be in accordance with all applicable City of Eagle Codes unless specifically approved by the Commission and/or Council. 27. Any changes to the plans and specifications upon which this approval is based, other than those required by the above conditions, will require submittal of an application for modification and approval of that application prior to commencing any change. Any change by the applicant in the planned use of the property which is the subject of this application, shall require the applicant to comply with all rules, regulations, ordinances, plans, or other regulatory and legal restrictions in force at the time the applicant or its successors in interest submits application to the City of Eagle for a change to the planned use of the subject property. 28. No public board, agency, commission, official or other authority shall proceed with the construction of or authorize the construction of any of the public improvements required by the Eagle City Code Title 9 "Land Subdivisions" until the final plat has received the approval of the City Council (ECC 9-6-S (A) (2». After Council approval of the final plat, the applicant may construct any approved improvements Page 13 of 15 K:\Planning Dept\Eagle Applications\SUBS\2001\Autumncrest pzf.doc before the City Engineer signs the final plat. The applicant shall provide a financial guarantee of performance in the amount of 150% of the total estimated cost for completing any required improvements (see resolution 98-3) prior to the City Engineer signing the final plat. The financial guarantee shall be a Letter of Credit, Certificate of Deposit, cash deposit or certified check. 29. In accordance with Eagle City Code, failure to obtain a recorded final plat for the subdivision within one year following City Council approval shall cause this approval to be null and void, unless a time extension is granted by the City Council. 30. Prior to submitting the final plat for recording, the following must provide endorsements or certifications: Owners or dedicators, Registered Land Surveyor, County Engineer, Central District Health Department, Ada County Treasurer, Ada County Highway District Commissioners, City Engineer, and City Clerk. 31. The City's actions on the application does not grant the applicant any appropriation of water or interference with existing water rights. The applicant indemnifies and holds the City harmless for any and all water rights, claims in any way associated with this application. CONCLUSIONS OF LAW: 1. The application for this item was received by the City of Eagle on May 31,2001. 2. Notice of Public Hearing on the application for the Eagle Planning and Zoning Commission was published in accordance for requirements of Title 67, Chapter 65, Idaho Code and the Eagle City ordinances on July 21, 2001. Notice of this public hearing was mailed to property owners within three-hundred feet (300-feet) of the subject property in accordance with the requirements of Title 67, Chapter 65, Idaho Code and Eagle City Code on July 18, 2001. Requests for agencies' reviews were transmitted on June 1, 2001, in accordance with the requirements of the Eagle City Code. 3. The Commission reviewed the particular facts and circumstances of this proposed preliminary plat (PP-5-01) and based upon the information provided concludes that the proposed preliminary plat application is in accordance with the City of Eagle Title 9 (Subdivisions) because: a. The requested preliminary plat complies with the density of the approved zoning designation of R-E (Residential); and b. Will be harmonious with and in accordance with the general objectives of title 9 of the Eagle City Code since the development is consistent with the Comprehensive Plan and provides the required improvements for a subdivision; and c. Will be designed, constructed, operated and maintained to be harmonious and appropriate in appearance with the existing and intended character of the general vicinity and that such use will not change the essential character of the same area, since the proposed residential use is in accordance with the residential land use designation of this area shown within the Comprehensive Plan; and d. Will not create excessive additional requirements at public cost for facilities and services as the site will be served by septic systems that must be approved by Central District Health and will use public water to be served by the water company having jurisdiction in that area. Fire protection will be available from the Eagle Fire District Page 14 of IS K:\Planning Dept\Eagle Applications\SUBS\200 1 \Autumncrest pzf.doc and fife hydrants will be provided where required; and e. Will have vehicular approaches to the property designed to not create an interference with traffic on surrounding public thoroughfares since the project is required to be reviewed and approved the Ada County Highway District and is subject to the conditions herein; and f. This development is in continuity with the capital improvement program since the required public improvements are required as conditioned herein, or are expected to be installed with the development of individual lots as conditions of approval; and g. That based upon agency verification and additional written comments of the Eagle Fire Department and the Ada County Highway District, or as conditioned herein, there is adequate public financial capability to support the proposed development; and h. That any health, safety and environmental problems that were brought to the Commission's attention have been adequately addressed by the applicant or will be conditions of final plat approval as set forth within the conditions of approval above. DATED this 1st day of October 2001. PLANNING AND ZONING COMMISSION OF THE CITY OF EAGLE Ada County, Idaho ~~iL ¡q/'/Ol John Franden, Chairman 5,,~ Ù.¿ztc~.5 '~...~ ~ 0' Jt.t (} (j~.' /""", :(~. . tJ¡ ~fOR..,. \ c..° 4' . *[ ..ËÃI)*I \~.. ~.c(.~9J '!.~ Of ~~ ", ~(~...,..tI ATTEST: Page 15 of 15 K:\Planning Dept\Eagle Applications\SUBS\200 1 \Autumncrest pzf.doc