Flood Control - Elevation Certificate - 1770 S Isla Del Rio Way - Williamson River Ranch Sub 01 - 4/23/2019U.S. DEPARTMENT OF HOMELAND SECURITY
660-0008
Federal Emergency Management Agency Expiration l
rationDa a November 30, 2018
National Flood Insurance Program I..
ELEVATION CERTIFICATE
Important: Follow the instructions on pages 1-9.
Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
SECTION A — PROPERTY INFORMATION FOR INSURANCE COMPANY USE
Al. Building Owner's Name Policy Number:
Ti and Jessica Slaven
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and
Box No. Company NAIC Number:
1770 S. Isla Del Rio Way
City State ZIP Code
Eagle Idaho 83616
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
Portion of Parcel No. S0516449800; and to be recorded as Lot 6 Block 5 Williamson River Ranch Subdivision No. 1
A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential
A5. Latitude/Longitude: Lat. N 43°40'44.68" Long. W116°20'10.25" Horizontal Datum: ❑ NAD 1927
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
A7. Building Diagram Number 9
A8. For a building with a crawlspace or enclosure(s)
a) Square footage of crawlspace or enclosure(s) 2,682 sq ft
❑x NAD 1983
b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 10
c) Total net area of flood openings in A8.b 750 sq in
d) Engineered flood openings? ❑ Yes ❑x No
A9. For a building with an attached garage:
a) Square footage of attached garage 1,245 sq ft
b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 0
c) Total net area of flood openings in A9.b 0 sq in
d) Engineered flood openings? ❑ Yes ❑x No
SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number B2. County Name B3. State
City of Eagle 160003 Ada ii Idaho
B4. Map/Panel B5. Suffix B6. FIRM Index B7. FIRM Panel I B8. Flood Zone(s) B9. Base Flood Elevation(s)
Number Date Effective/ (Zone AO, use Base
Revised Date Flood Depth)
16001 C0162/162 H 02/19/2003 02/19/2003 AE 2570
B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item 139:
❑x FIS Profile ❑ FIRM ❑ Community Determined ❑ Other/Source:
B11. Indicate elevation datum used for BFE in Item 139: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source:
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ❑x No
Designation Date: ❑ CBRS ❑ OPA
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 1 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
1770 S. Isla Del Rio Way
City State ZIP Code
Company NAIC Number
Eagle Idaho 83616
SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ❑x Finished Construction
*A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations — Zones Al—A30, AE, AH, A (with BFE), VE, V1—V30, V (with BFE), AR, AR/A, AR/AE, AR/A1—A30, AR/AH, AR/AO.
Complete Items C2.a—h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters.
Benchmark Utilized: see comments Vertical Datum: NAVD88
Indicate elevation datum used for the elevations in items a) through h) below.
❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source:
Datum used for building elevations must be the same as that used for the BFE.
Check the measurement used.
a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 2571 6 ❑x feet ❑ meters
b) Top of the next higher floor 2575 0 ❑x feet ❑ meters
c) Bottom of the lowest horizontal structural member (V Zones only) 0. 0 ❑x feet ❑ meters
d) Attached garage (top of slab) 2574 4 ❑x feet ❑ meters
e) Lowest elevation of machinery or equipment servicing the building 2574 5 ❑x feet ❑ meters
(Describe type of equipment and location in Comments)
f) Lowest adjacent (finished) grade next to building (LAG) 2574 3 ❑x feet ❑ meters
g) Highest adjacent (finished) grade next to building (HAG) 2574 8 ❑x feet ❑ meters
h) Lowest adjacent grade at lowest elevation of deck or stairs, including 2574 8 ❑x feet ❑ meters
structural support
SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information
l certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false
statement may be punishable by fine or imprisonment under 18 U. S. Code, Section 1001.
Were latitude and longitude in Section A provided by a licensed land surveyor? ❑ Yes ❑ No ❑ Check here if attachments.
Certifiier's Name License Number
Sean P.Sullivan 13446 (f►�.
Title CE
PLS i
Company Name 0
13
David Evans & Associates Inc.
J�1
Address
—9925 W. Emerald Street
City State ZIP Code �P
Boise Idaho 83704
Signature Date Telephone
04/23/2019 (208) 585-5858
Copy all pages of this Elevationrtifica a and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
Comments (including type of equipment and location, per C2(e), if applicable)
A Scribed "X" in the concrete walk in front of site with a written elevation of 2573.24 was used for the TBM. This control was found for
existing construction for Williamson River Ranch Subdivision No. 1 and verified to be on the NAVD88 Vertical Datum.
The Elevation in C2(e) is an Air Conditioning Pad.
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
1770 S. Isla Del Rio Way
City State ZIP Code
Company NAIC Number
Eagle Idaho 83616
SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED)
FOR ZONE AO AND ZONE A (WITHOUT BFE)
For Zones AO and A (without BFE), complete Items E1—E5. If the Certificate is intended to support a LOMA or LOMR-F request,
complete Sections A, B,and C. For Items E1—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only,
enter meters.
E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below
the highest adjacent grade (HAG) and the lowest adjacent grade (LAG).
a) Top of bottom floor (including basement,
crawispace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
b) Top of bottom floor (including basement,
crawlspace, or enclosure) is _ ❑ feet ❑ meters ❑ above or ❑ below the LAG.
E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions),
the next higher floor (elevation C2.b in
the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG.
E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG
E4. Top of platform of machinery and/or equipment
servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG
E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's
floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G.
SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION
The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA -issued or
community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge.
Property Owner or Owner's Authorized Representative's Name
Address City State ZIP Code
Signature Date Telephone
Comments
❑ Check here if attachments.
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 3 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number:
1770 S. Isla Del Rio Way
City State i ZIP Code Company NAIC Number
Eagle Idaho 83616
SECTION G — COMMUNITY INFORMATION (OPTIONAL)
The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete
Sections A, B. C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement
used in Items G8—G10. In Puerto Rico only, enter meters.
G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor,
engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation
data in the Comments area below.)
G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA -issued or community -issued BFE)
or Zone X10.
G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes.
G4. Permit Number G5. Date Permit Issued
G6. Date Certificate of
Compliance/Occupancy Issued
G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement
G8. Elevation of as -built lowest floor (including basement)
of the building ❑ feet ❑ meters Datum
G9. BFE or (in Zone AO) depth of flooding at the building site:
G10. Community's design flood elevation:
I Local Official's Name
Community Name
I Signature
Title
Telephone
Date
Comments (including type of equipment and location, per C2(e), if applicable)
❑ feet ❑ meters Datum
❑ feet ❑ meters Datum
❑ Check here if attachments.
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 4 of 6
BUILDING PHOTOGRAPHS OMB No. 1660-0008
ELEVATION CERTIFICATE See Instructions for Item A6. Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number:
1770 S. Isla Del Rio Way
City State ZIP Code Company NAIC Number
Eagle Idaho 83616
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the
instructions for Item A6. Identify all photographs with date taken; "Front View" and 'Rear View'; and, if required, "Right Side View" and
"Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or
vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page.
Photo One
Photo One Caption Front View
Photo Two
Photo Two Caption Right Side View
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 5 of 6
BUILDING PHOTOGRAPHS OMB No. 1660-0008
ELEVATION CERTIFICATE Continuation Page Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number:
1770 S. Isla Del Rio Way
City State ZIP Code Company NAIC Number
Eagle Idaho 83616
If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs
with: date taken; "Front View" and 'Rear View'; and, if required, 'Right Side View" and "Left Side View." When applicable,
photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8.
Photo One
Photo One Caption Rear View
Amp
Photo Two
Photo Two Caption Left Side View
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 6 of 6