Service Solicited - 2023 - Precision Pumping Systems - Pamela Baker Park Pump Station r7S\-
,
•
6 r
Prec•isliort Pumping Systerns
C20'3}323-5300-wvu.Ga,PPS.us
PROJECT:PAMELA BAKER PARK OFFER DATE:7/13/2023 t OFFER EXPIRES
QUOTE#:SCS-18446 REVISION:A VALID FOR:30 DAYS 8/12/2023
To ensure correct order processing,you must reference QUOTE#18446 and REVISION A on Purchase Order
CONTACT:Jesse Sexton(208)-484-7576 LOCATION CITY:EAGLE
MODEL NUMBER:S#/N2S010X00135-075MS3B243ONS3 STATE:ID-IDAHO
EST'_.. -..
Design Point 1
Design Flow Rate-GPM: 135 Voltage: ;ylt. 77P-IICA Electrical Loads AMPS
Intake Pressure-PSI: Phase: 3 DISCONNECT 100
Station Pressure-PSI: 75 Hertz: 60 NEC FLA 84
Discharge Pressure-PSI: 75
NOT VERIFIED: SUM?DEPTH
I S%T-.p .. SE'...,,ENCE: ! STANDBY
FUNCTION Q I P )PUMP PERFORMANCE RPM TYPE!BRAND MOTOWENCLOSURE
MAIN/DUTY 2 10 135 GPM€175'TDH 3600 SUBMERSIBLE TURBINE SUB-TURBINE
XYLEM-GOULDS
•
+SPECIAL MOTOROESIGN/ADDITIONS
Premium Efficiency Motors(Default for all standard motors provided)
YSTEM TYPE: SUBMERSIBLE TURBINE
INTAKE SOURCE: NON-POTABLE-QUALITY UNKNOWN
DISCHARGE USE: NON-POTABLE
FILTER/STRAINER SYSTEM: MINI SIGMA 3"/SCREEN=130 p QTY= 1
PUMP STATION ENCLOSURE: MARINE GRADE ALUMINUM -
PUMP STATION FLOW METER: BADGER MAG METER
SKID BASE SIZE(INCHES): 48 X 96 Estimated-Do not use for construction.Contact PPS for detailed drawing/info.
INCLUDES:START-UP,CALIBRATION,TRAINING and ELECTRICAL COMPONENT WARRANTY EXTENSION TO 3 YEARS*
INCLUDES 1 PPS TECHNICIAN FOR A MAXIMUM OF 6 HOURS ON SITE FOR START-UP AND CALIBRATION OF PUMP STATION 8 OPERATOR TRAINING
-MUST BE SCHEDULED A MINIMUM OF 2 WEEKS IN ADVANCE-ANY ADDITIONAL TIME REQUIRED WILL BE CHARGED TO CUSTOMER
-CERTIFIED START UP EXTENDS WARRANTY OF ALL COMPONENTS INSIDE ELECTRICAL CONTROL PANEL(when pr;;.Med)TO A TOTAL OF 3•YEARS
•UL QCZJ Certified pumping system
•This quote/estimate is for a factory tested system and/or components.
•The pump station shall include all pumps described above,as well as all necessary valves and piping(See details below).
•If provided the variable frequency control panel for the pump station will be prewired and pretested.
•If provided the system will be controlled by a PLC and HMI Touchscreen with programming written specific to the project.
•Control Panel is NEMA 3R manufactured for INDOOR operation.
)ESIG+I CRITERIA(Quotation is based-on the following specilicabonsn .fit 6
•Customer supplied design point information.
•Information noted in the above Design Details&Pump Selections.Deviation from details specified above may impact pricing
•PPS is not responsible for any errors or omissions due to incomplete or inaccurate information.
PUMP STATION.QUOTATION; OTY PRICE
BASE PRICE-PACKAGED PUMPING STATION: 1 $65,445 Int.
t Due to current unsettled market conditions this offer will expire on 12-Aug-2023, Please contact PPS for updated offer when required.
._E:+ S,
to Ail systems over$100,000 and aft Custom.Eng:neered systems require pre-rsayment terms.Weiss contact the PPS S*iesnereon for MI Payment deals,
Precision Pumping Systems:s an Dt M and does not accent au• nntractor iw 0. AO Pesto ace Wm-
See Complete Terms and Cond'I'ons of Si`nfor full de;r
......LOCAL SYSTEMS ARE FOB PPS FACTORY-SEE DEUVERY OPTION IF OFFERED FOB PPS FACTORY
OPTION-DELK ERY&Sr"ii'.up OF PUMP STATION FLUSH LeIs CW SCREEN uIETIE-ws INCLUDED'aulli $ tnt. •^
bEI-IVER PUMP'STATIONS SET STATION AND PUMPS WI CRANE-CONNECTION TO MAINUNE.SUCTION AND OTHER SITE PIPING NOT INCLUDED —
'OPTION-MAINLINE"FIE-tilt-f]atidentplattOYV .;: r--k; ;...,,,,.11111W l" •- 31109 Int.
CUSTOMER TO STUB MAINLINE VERTICALLYABOVE GROUND AS SHOWN ON PLANS.IMPROPER MAINLINE STUBS WILL RESULT IN ADDITIONAL COSTS.
Council Approval:
TOTAL PRICE WITH OPTIONS $67,075 Int. ,
See Terns Ea-Cont i ions far details
TELEPHONE TECHNICAL SUPPORT: Free-of-charge for the life of your product(During normal operating/business hours)
Precision Pumping Systems(PPS)warrants that its products and systems will be free from defects in material and workmanship for a period of thirty-six
(361 months from the date of placing the equipment in operation or fourty[401 months from the date of completion of manufacture of the equipment,
whichever shall occur first.
Initial start-up and preventative maintenance must be performed by an authorized PPS representative or the warranty shall be void. This warranty does
not apply to equipment that has been damaged,misapplied or modified in any way.
*Three year electronic warranty extension offered with certified start-up is only available when ABB®J or Mitsubishi®drives are incorporated.
SHIPMENT/DELIVERY:All reasonable efforts will be made to meet the requested shipment date after the receipt of a signed purchase order and
approval of submittal(s). Manufacturer will not be held liable for delays in shipment or delivery.
•Appropriate power to be provided by others-voltage&phase specified above from Customer provided information
•Offloading&set up by others(unless delivery/set-up option offered and accepted)
•Wet well,concrete pad(s),intake structure or other civil works to be provided by others.
•Tie-in to main line and flush lines to be performed by others(unless tie-in option offered and accepted)
•No taxes are included in this quotation.
`CO ST.rl `x.SY.r..?..-`.M
•ENVIRONMENTAL DESIGN: NEMA 3R cabinet manufactured for INDOOR operation
•MOTOR STARTING PRIMARY: VFD+ALTERNATION CONTACTOR
•VFD MODEL: ABB ACQ580
•PANEL COOLING: FORCED AIR
•CONTROL SYSTEM MODEL NUMBER: MMC2X010-243-DPP-MAC-AF-30GFCI-U3F-TE-PLC6E-HG7C-VZW
•CONTROL PANEL MODEL NUMBER: PAMELA BAKER-VFD PANEL-V1[REV-DEFAULT]
•CONTROL PANEL SIZE: H=42" W+D=3616" FEET=3" TOTAL HEIGHT=45"
•SPECIFIED KAIC: NONE SPECIFIED
1401010,
•HARMONICS MITIGATION KIT-compliance with IEEE-519 standards YES-EXTERNAL ENCLOSURE MOUNTED
•VOLTAGE MONITOR
'•WLRELESS CAPABLE-Modem provided-No service included
•GFCL Outlet(20A DUPLEX)-Control Panel Powered
•UL Listed and Labeled(UL 508A)
•Ethernet Capable for Internet Access
•Clock Start Relay;24vac(or 120vac)
'•System Fault Logger
•VFD Sleep By Flow;Wake By Pressure
•Adjust VFD SleepSettings on HMI
•Single Motor Controller
•Single Main+Jockey Controller
•Multi-Motor Controller with Alternation
•EMAIL Alarm Capability
•Hand/Off/Auto Selector
•Manual VFD Speed Control-Dial(Potentiometer)
•Labeled Field Terminal Wiring Strip
•Main-Line Slow Fill Routine
•HMI Password Protection
•PID Set-Point Trimming via Level/Intake
•Trend Data lo-:in:with u•Toad to USB
PIPE COMPOSITION:
GALVANIZED ASTM A53 GROUP B STEEL PIPE-HOT DIP GALVANIZED
BASE COMPOSITION:
GALVANIZED ASTM A36 STEEL PLATE-BREAK PRESS FOLDED-HOT DIP GALVANIZED
GENERAL DETAILS:
•PUMP CHECK VALVE(S) GROOVED-Valmatic
•PUMP ISOLATION VALVES(5) GROOVE BFV
•STATION ISOLATION VALVES(S) GROOVE BFV
•PRESSURE CLASS: AW``AlA D[175 PSI]
•PRESSURE REUEF VALVE 2"ClaVal 50-13
COATING DETAILS:
Pipe Interior: GALVANIZED
Pipe Exterior: GALVANIZED
Skid Base: GALVANIZED
Enclosure: PPS BEIGE
SENSOAS
•.•oiwi.arge IPmexviareGaugge 2 2.5"SS Case Liquid idled PSI= 0-160
•DisctLaga Premsure lnwsr,miWsr 1 IFM Stainless Steel PSI= 0-200
•Low Water Float 1
•High Pressure S.s-1ch 1
O EMElit
•Intake Scram:Supply Valve YES-1"
•3/4"Air Release Valve 2
•All bare carbon steel is coated with PolyesterTGIC baked on powder coating
•Hose bib connection(where applicable)
Sample Tap for Potable Systems(where applicable)
•Manifold drains(where applicable)
•ENCLOSURE TYPE: MARINE GRADE ALUMINUM
•NUMBER OF ACCESS DOORS: 2
•LID REMOVAL: LIFT OFF
•EXTERIOR SIDE FINISH: MARINE GRADE ALUMINUM
•ROOF COVERING: MARINE GRADE ALUMINUM
•ROOF GEOMETRY: GABEL SIDE to SIDE
•ALL ACCESS LOCKABLE
•REMOVABLE SIDE PANELS FOR ACCESS ON MARINE GRADE ALUMINUM ENCLOSURES
•ALL ALUMINUM SURFACES INCLUDE BAKED ON POWDER COAT FINISH
PRECISION MIMIC SYSTEMS(PPS)STANDARD TERMS AND CONDJTIONS APPLY
w-�Y
�.._.,. PPS 3 ..
Precision Pumping Systems ump., ion
(208)323-5300•www.GoPPS.us
PUMP STATION QUOTATION
PROJECT:PAMELA BAKER PARK OFFER DATE:7/13/2023 t OFFER EXPIRES
QUOTE#:SCS-18446 REVISION:A VALID FOR:30 DAYS 8/12/2023
To ensure correct order processing,you must reference QUOTE#18446 and REVISION A on Purchase Order
CONTACT:Jesse Sexton(208)-484-7576 LOCATION CITY:EAGLE
MODEL NUMBER:S##V2S010X00135-075MS3B243ONS-3 STATE:ID-IDAHO
DESIGN DETAILS
Design Point: 1
Design Flow Rate-GPM: 135 Voltage: 240 Electrical Loads AMPS
Intake Pressure-PSI: Phase: 3 DISCONNECT 100
Station Pressure-PSI: 75 Hertz: 60 NEC FLA 84
Discharge Pressure-PSI: 75
NOT VERIFIED: SUMP DEPTH
PUMP AND MOTOR DETAILS .:c;ut:N E: LE. s:alvuul
FUNCTION QTY HP PUMP PERFORMANCE RPM TYPE/BRAND MOTOR ENCLOSURE
MAIN/DUTY 2 10 135 GPM @ 175'TDH 3600 SUBMERSIBLE TURBINE SUB-TURBINE
XYLEM-GOULDS
SPECIAL MOTOR DESIGN/ADDITIONS
Premium Efficiency Motors(Default for all standard motors provided)
SYSTEM OVERVIEW
SYSTEM TYPE: SUBMERSIBLE TURBINE
INTAKE SOURCE: NON-POTABLE-QUALITY UNKNOWN
DISCHARGE USE: NON-POTABLE
FILTER/STRAINER SYSTEM: MINI SIGMA 3"/SCREEN=130 N QTY= 1
PUMP STATION ENCLOSURE: MARINE GRADE ALUMINUM
PUMP STATION FLOW METER: BADGER MAG METER
SKID BASE SIZE(INCHES: 48 X 96 Estimated-Do not use for construction.Contact PPS for detailed drawing/info.
INCLUDES:START-UP,CALIBRATION,TRAINING and ELECTRICAL COMPONENT WARRANTY EXTENSION TO 3 YEARS"
INCLUDES 1 PPS TECHNICIAN FOR A MAXIMUM OF 6 HOURS ON SITE FOR START-UP AND CALIBRATION OF PUMP STATION&OPERATOR TRAINING
-MUST BE SCHEDULED A MINIMUM OF 2 WEEKS IN ADVANCE-ANY ADDITIONAL TIME REQUIRED WILL BE CHARGED TO CUSTOMER
-CERTIFIED START UP EXTENDS WARRANTY OF ALL COMPONENTS INSIDE ELECTRICAL CONTROL PANEL(when proNded)TOA TOTAL OF 3'YEARS
•UL QCZJ Certified pumping system
•This quote/estimate is for a factory tested system and/or components.
•The pump station shall include all pumps described above,as well as all necessary valves and piping(See details below).
•If provided the variable frequency control panel for the pump station will be prewired and pretested.
•If provided the system will be controlled by a PLC and HMI Touchscreen with programming written specific to the project.
•Control Panel is NEMA 3R manufactured for INDOOR operation.
DESIGN CRITERIA(Quotation is based on the following specifications/information):
•Customer supplied design point information.
•Information noted in the above Design Details&Pump Selections.Deviation from details specified above may impact pricing
•PPS is not responsible for any errors or omissions due to incomplete or inaccurate information.
PR''NG PUMP STAT "' \TION QTY PRICE
BASE PRICE-PACKAGED PUMPING STATION: 1 $65,445
nsettled market co r S 1' e will expire on 12-Aug-2023. Please contact PPS for updated offer when required.
PAYMENT TERMS
•AM systems over$100,000 and all Custom Engineered systems require prepayment terms.Please contact the PPS Salesperson for full payment details.
•Precision Pumping Systems is an OEM and does not accept sub-contractor payment and performance terms.
•See Complete Terms and Conditions of Sale for full details.
11111111111111111.1111111111.1.111111.11111111 .1.111111111.1111111111111111111111.1111
LOCAL SYSTEMS ARE FOB PPS FACTORY-SEE DELIVERY OPTION IF OFFERED FOB PPS FACTORY
OPTIONS [NOT INCLUDED IN BASE PRICE ABOVE,
OPTION-DELIVERY&SET-UP OF PIIIISTATION FLUSH LNE/CW SCREEN LINE TIE-INS INCLUDED $561 Int. `'s--
DELIVER PUMP STATION&SET STATION AND PUMPS WI CRANE-CONNECTION TO MAINLINE,SUCTION AND OTHER SITE PIPING NOT INCLUDED
OPTION-MAINLINE TIE-IN-FIELD FABRICATED ELBOW 11.11111111 $1,069 Int.
CUSTOMER TO STUB MAINLINE VERTICALLY ABOVE GROUND AS SHOWN ON PLANS.IMPROPER MAINLINE STUBS WILL RESULT IN ADDITIONAL COSTS.
TOTAL PRICE WITH OPTIONS $67,075 Int. Z
WARRANTY [ See Terms&Conditions for details j
TELEPHONE TECHNICAL SUPPORT: Free-of-charge for the life of your product(During normal operating/business hours)
Precision Pumping Systems(PPS)warrants that its products and systems will be free from defects in material and workmanship for a period of thirty-six
[36)months from the date of placing the equipment in operation or fourty[401 months from the date of completion of manufacture of the equipment,
whichever shall occur first.
Initial start-up and preventative maintenance must be performed by an authorized PPS representative or the warranty shall be void. This warranty does
not apply to equipment that has been damaged,misapplied or modified in any way.
*Three year electronic warranty extension offered with certified start-up is only available when A88®or Mitsubishi®drives are incorporated.
SHIPMENT
SHIPMENT/DELIVERY::All reasonable efforts will be made to meet the requested shipment date alter the receipt of a signed purchase order and
approval of submittal(s). Manufacturer will not be held liable for delays in shipment or delivery.
NOTES
•Appropriate power to be provided by others-voltage&phase specified above from Customer provided information
•Offloading&set up by others(unless delivery/set-up option offered and accepted)
•Wet well,concrete pad(s),intake structure or other civil works to be provided by others.
•Tie-in to main line and flush lines to be performed by others(unless tie-in option offered and accepted)
•No taxes are included in this quotation.
CONTROL SYSTEM DETAIL,
•CONTROLLER: IDEC PLC6e-PLUS
•HMI: IDEC 7.0"COLOR TOUCH SCREEN
•ENVIRONMENTAL DESIGN: NEMA 3R cabinet manufactured for INDOOR operation
•MOTOR STARTING PRIMARY: VFD+ALTERNATION CONTACTOR
•VFD MODEL: ABB ACQ580
•PANEL COOLING: FORCED AIR
•CONTROL SYSTEM MODEL NUMBER: MMC2X010-243-DPP-MAC-AF-30GFCI-U3F-TE-PLC6E-HG7C-VZW
•CONTROL PANEL MODEL NUMBER: PAMELA BAKER-VFD PANEL-V1[REV-DEFAULT]
•CONTROL PANEL SIZE: H=42" W+D=3616" FEET=3" TOTAL HEIGHT=45"
•SPECIFIED KAIC: NONE SPECIFIED
•HARMONICS MITIGATION KIT-compliance with IEEE-519 standards YES-EXTERNAL ENCLOSURE MOUNTED
•VOLTAGE MONITOR
•WIRELESS CAPABLE-Modem provided-No service included
•GFCI Outlet(20A DUPLEX)-Control Panel Powered
•UL Listed and Labeled(UL 508A)
•Ethernet Capable for Internet Access
•Clock Start Relay;24vac(or 120vac)
•System Fault Logger
•VFD Sleep By Flow;Wake By Pressure
•Adjust VFD Sleep Settings on HMI
•Single Motor Controller
•Single Main+Jockey Controller
•Multi-Motor Controller with Alternation
•EMAIL Alarm Capability
•Hand/Off/Auto Selector
•Manual VFD Speed Control-Dial(Potentiometer)
•Labeled Field Terminal Wiring Strip
•Main-Line Slow Fill Routine
•HMI Password Protection
•PID Set-Point Trimming via Level/Intake
•Trend Data lo::in:with u'load to USB
MECHANICAL DETAILS
PIPE COMPOSITION:
GALVANIZED ASTM A53 GROUP B STEEL PIPE-HOT DIP GALVANIZED
BASE COMPOSITION:
GALVANIZED ASTM A36 STEEL PLATE-BREAK PRESS FOLDED-HOT DIP GALVANIZED
GENERAL DETAILS:
•PUMP CHECK VALVE(5) GROOVED-Valmatic
•PUMP ISOLATION VALVES(S) GROOVE BFV
•STATION ISOLATION VALVES(S) GROOVE BFV
•PRESSURE CLASS: AVWVA D[175 PSI]
•PRESSURE RELIEF VALVE 2"ClaVal 50-13
COATING DETAILS:
Pipe Interior: GALVANIZED
Pipe Exterior: GALVANIZED
Skid Base: GALVANIZED
Enclosure: PPS BEIGE
SENSORS
•Discharge Pressure Gauge 2 2.5"SS Case Liquid Filled PSI= 0-160
•Discharge Pressure Transmitter 1 IFM Stainless Steel PSI= 0-200
•Low Water Float 1
•High Pressure Switch 1
OTHER
•Intake Screen Supply Valve YES-1"
•3/4"Air Release Valve 2
•All bare carbon steel is coated with Polyester TGIC baked on powder coating
•Hose bib connection(where applicable)
•Sample Tap for Potable Systems(where applicable)
•Manifold drains where applicable)
ENCLOSURE DETAILS
•ENCLOSURE TYPE: MARINE GRADE ALUMINUM
•NUMBER OF ACCESS DOORS: 2
•LID REMOVAL: LIFT OFF
•EXTERIOR SIDE FINISH: MARINE GRADE ALUMINUM
•ROOF COVERING: MARINE GRADE ALUMINUM
•ROOF GEOMETRY: GABEL SIDE to SIDE
•ALL ACCESS LOCKABLE
•REMOVABLE SIDE PANELS FOR ACCESS ON MARINE GRADE ALUMINUM ENCLOSURES
•ALL ALUMINUM SURFACES INCLUDE BAKED ON POWDER COAT FINISH
(PRECISION PUMPING SYSTEMS(PPS)STANDARD TERMS AND CONDITIONS APPLY