Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Flood Control - Elevation Certificate - 829 S Heron Pointe Way - Mace River Ranch Sub No 05 - 6/6/2018
4-i7s�2lia U.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660 ODD8 Federal Emergency Management Agency Expiration Date: November 30, 2018 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agenticompany, and (3) building owner SECTION A —PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: PAUL TOFFEL A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Company NAIC Number: 829 S. HERON POINTE WAY City State ZIP Code EAGLE Idaho 83616 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) LOT 122, BLOCK 1, MACE RIVER RANCH SUB NO. 5 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) RESIDENTIAL A5. latitude/Longitude: Lat. 43.687688 Long. -116.368636 Horizontal Datum: ❑ NAD 1927 ❑X NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number 9 A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) 3190.00 sq It b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 0 c) Total net area of flood openings in A8.b 0.00 sq in d) Engineered flood openings? ❑ Yes 9 No A9. For a building with an attached garage: a) Square footage of attached garage 1415.00 sq It b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 0 c) Total net area of flood openings in Ag.b 0.00 sq in d) Engineered flood openings? ❑ Yes ® No SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State EAGLE, 160003 ADA Idaho B4. Map/Panel Number B5. Suffix Be. FIRM Index Date B7. FIRM Panel Effective/ B8. Flood Zone(s) 9. Base Flood Elevation(s) (Zone AO, use Base Flood Depth) Revised Date [2548.90 16001CO153 H 10-02-2003 02-19-2003 X(SHADED) B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9: ❑ FIS Profile ❑ FIRM ❑ Community Determined ® Other/Source: LOMR-F CASE NO. 17-10-0133A B11. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 © NAVD 1968 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes © No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 1 of 6 ELEVATION CERTIFICATE OMB No, 1660-0008 FYniratinn rlate: Novembe, an 9018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 829 S. HERON POINTE WAY State ZIP Code Company NAIC Number EAGLE Idaho 83616 SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings" ❑ Building Under Construction* ® Finished Construction 'A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations — Zones Al—A30, AE. AH, A (with BFE), VE, V1—V30, V (with BFE), AR, AR/A, AR/AE, AR/A7—A30, ARIAH, AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item AT In Puerto Rico only, enter meters. Benchmark Utilized: See Note 1, Section D Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 ® NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used, a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 2549.5 0 feet ❑ meters b) Top of the next higher floor 2552.8 feel ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A 2) feet ❑ meters d) Attached garage (top of slab) 2552.1 ❑K feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building (Describe type of equipment and location in Comments) 2550.5❑X feet ❑ meters f) Lowest adjacent (finished) grade next to building (LAG) 2551.8 ❑X feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 2552.1 feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs. including structural support 2552.3 ❑X feet ❑ meters SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code. Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? © Yes ❑ No ❑ Check here if attachments. Certifier's Name License Number Cody M. McCammonIdaho PLS 11779 g0 6tSTE,� sfi Title Land Surveyor t�! 1 Company Name Idaho Survey Group t1 � Address 9955 W. Emerald St. City State ZIP Code Boise Idaho 83704 Signatu` Date Telephone Ext. L.----� 0E06-2018 (208)846-8570 Copy all page of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) 1) Station Blue is a local private GPS station tied to the local HARN Network (NAVD88) 2) FEMA LOMR-F Case No. 17-10-0133A, December 06, 2016, classifies this Lot in Shaded Zone X 3) Projected BFE for Lot is 2548.9 at adjacent AE Zone 4) Lowest equipment servicing the building is heat ducts in crawlspace at 2550.5. The AC Unit elevation = 2552.3, Water Heater and Furnace elevation = 2552.6. Lowest structural support are columns on front and back patios elevation = 2552.3 5)No exterior crawlspace vents- Crawl space air circulation system. FEMA Form 086-0-33 (7115) Replaces all previous editions. Form Page 2 of 6 BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE Continuation Pane C I. F IMPORTANT: In these spaces, copy the corresponding information from Section ,.r.......... ..... ii. A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 829 S. HERON POINTE WAY City State ZIP Code Company NAIC Number EAGLE Idaho 83616 If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear Vievl'; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. 4! r. PM1oro Throe Photo Three Caption Right Side View Clear Photo Three '11:x`4• `,1 .1 .4 'n a.r F K Photo Fou, Photo Four Caption Left Side View Clear Photo Four FEMA Form 086-0-33 (7115) Replaces all previous editions. Form Page 6 of 6