Loading...
Findings - CC - 2018 - PP/FP-03-17 - Pp And Fp For Piccadilly Village Subd No. 2BEFORE THE EAGLE CITY COUNCIL IN THE MATTER OF AN APPLICATION FOR A COMBINED PRELIMINARY/FINAL PLAT FOR PICCADILLY VILLAGE SUDIVISION NO. 2 FOR OLD TOWN I, LLC FINDINGS OF FACT AND CONCLUSIONS OF LAW CASE NUMBER PP/FP-03-17 The above -entitled combined preliminary/final plat application came before the Eagle City Council for their action on February 13, 2018, at which time public testimony was taken and the public hearing was closed. The Eagle City Council, having heard and taken oral and written testimony, and having duly considered the matter, makes the following Findings of Fact and Conclusions of Law; FINDINGS OF FACT: A. PROJECT SUMMARY: Old Town I, LLC, represented by Mark L. Butler, is requesting combined preliminary/final plat approval for Piccadilly Village Subdivision No. 2, a 3 -lot commercial subdivision (re -subdivision Lot 14, Block 1, Piccadilly Village Subdivision). The 1.75 -acre site is located at the southeast corner of North Echohawk Lane and East Hill Road at 220 South Echohawk Lane. B. APPLICATION SUBMITTAL: A Neighborhood Meeting was held on site at 6:00 PM, Wednesday, November 29, 2017, in compliance with the application submittal requirement of Eagle City Code. The application for this item was received by the City of Eagle on November 30, 2017. C. NOTICE OF PUBLIC HEARING: Notice of Public Hearing on the application for the Eagle Planning and Zoning Commission was published in accordance with the requirements of Title 67, Chapter 65, Idaho Code and the Eagle City Code on December 29, 2017. Notice of this public hearing was mailed to property owners within three -hundred feet (300 -feet) of the subject property in accordance with the requirements of Title 67, Chapter 65, Idaho Code and Eagle City Code December 26, 2017. Requests for agencies' reviews were transmitted December 7, 2017, in accordance with the requirements of the Eagle City Code. The site was posted in accordance with the Eagle City Code on January 4, 2018. Notice of Public Hearing on the application for the Eagle City Council was published in accordance with the requirements of Title 67, Chapter 65, Idaho Code and the Eagle City Code on January 25, 2018. Notice of this public hearing was mailed to property owners within three -hundred feet (300 - feet) of the subject property in accordance with the requirements of Title 67, Chapter 65, Idaho Code and Eagle City Code on January 22, 2018. The site was posted in accordance with the Eagle City Code on January 31, 2018. D. HISTORY OF RELEVANT PREVIOUS ACTIONS: On January 9, 2001, the City Council approved the findings of fact and conclusions of law for a rezone with development agreement, conditional use permit, planned unit development, and preliminary plat for Piccadilly Village Subdivision. (RZ-09-00/CU-09-00/PPUD-06-00 & PP -09- 00) On April 10, 2001, the City Council approved a design review application for the common area landscaping within Piccadilly Village Subdivision. (DR -54-00) Page 1 of 13 K:U'lanning Dept\Eagle Applications\SUBS \2017\ Piccadilly Village Sub No. 2 cct:ducx On February 12, 2002, City Council approved a final development plan and final plat for Piccadilly Village Subdivision. (FPUD-03-01/FP-06-01) On December 13, 2016, the City Council approved a development agreement modification for Mark Butler. (RZ-09-00 MOD) On December 12, 2017, the City Council approved a second development agreement modification for Mark Butler. (RZ-09-00 MOD2) E. COMPANION APPLICATIONS: None F. COMPREHENSIVE PLAN LAND USE MAP AND ZONING MAP DESIGNATIONS: G. H. Existing Proposed North of site South of site East of site West of site COMP PLAN DESIGNATION Mixed Use No Change Residential Three Mixed Use Commercial Mixed Use ZONING DESIGNATION MU -DA -P (Mixed Use with a development agreement — PUD) No Change MU -DA (Mixed Use with a development agreement [in lieu of a PUD]) MU -DA -P (Mixed Use with a development agreement — PUD) C -3 -DA (Highway Business District with a development agreement) MU -DA -P (Mixed Use with a development agreement — PUD) DESIGN REVIEW OVERLAY DISTRICT: Not located within the DDA, TDA, CEDA, or DSDA. SITE DATA: Total Acreage of Site — 1.75 -acres Total Number of Lots — 3 Commercial — 3 Industrial — 0 Common — 0 Total Number of Units — 0 Page 2 of 13 K:U'lanning Dept \Eagle Applications\SUBS \201TPiccadilly Village Sub No. 2 cct docx LAND USE Vacant lot (Lot 14, Block 1, Piccadilly Village Subdivision) Commercial subdivision ITD right-of-way Common lot (Piccadilly Village Subdivision) Proposed convenience store with fuel service Vacant commercial lot and single-family residential dwelling (Piccadilly Village Subdivision) Total Acreage of Any Out -Parcels — 0 ADDITIONAL SITE DATA PROPOSED REQUIRED Dwelling Units Per Gross Acre N/A N/A Minimum Lot Size 22,338 -square feet 5,000 -square -feet Minimum Lot Width 90 -feet 50 -feet Minimum Street Frontage 0 -feet 0 -feet Total Acreage of Common Area 0 -square feet 0* (measured as total landscaping of the entire site) Percent of Site as Common Area 0% 0* (measured as total landscaping of the entire site) * Note — Since this is a commercial subdivision a minimum of 10% of landscaping is required throughout the site. GENERAL SITE DESIGN FEATURES: Greenbelt Areas and Landscape Screening: Open Space: This is a commercial subdivision located within the MU zoning district, therefore, a minimum amount of open space is not required. However, a minimum of 10% of landscaping will be required throughout the site pursuant to Eagle City Code Section 8-2A-7 (B) (2). Storm Drainage and Flood Control: A master storm drainage plan will be reviewed by the City Engineer prior to construction of the first commercial building within the site. Lots are required to be graded so that all runoff runs either over the curb, or to drainage easements, and that no runoff shall cross any lot line onto another lot except within a drainage easement. Utility and Drainage Easements, and Underground Utilities: There are currently easements located adjacent to the boundary of the subdivision that were created when Piccadilly Village Subdivision was platted. The new subdivision will also contain a blanket public utility and drainage easement that will be centrally located (parking area) within the proposed subdivision. Fire Hydrants and Water Mains: Hydrants are to be located and installed as may be required by the Eagle Fire District. On-site Septic System (yes or no) — not allowed Preservation of Existing Natural Features: Staff is not aware of any existing natural features on the site which would be required to be preserved. Page 3 of 13 K:U'lanning Dept \Eagle Applications\SUBS \2017\I'iccadilly Village Sub No. 2 ccf.docx Preservation of Existing Historical Assets: Staff is not aware of any existing historical assets on the site. If during excavation or development of the site, any historical artifacts are discovered, state law requires immediate notification to the state. J. STREET DESIGN: Private or Public Streets: Public No new streets, street widening, or dedication of right-of-way to the Ada County Highway District is proposed with this application. All streets within this subdivision were previously approved with Not all of the proposed lots within this subdivision will have direct lot access to the public street. The plat shows an area for cross access and shared parking between the lots to the public streets for pedestrian and vehicular traffic and is to be noted as such on the final plat. Applicant's Justification for Private Streets (if proposed): None proposed Blocks Less Than 500': None Cul-de-sac Design: N/A Sidewalks: A five-foot (5') wide sidewalk currently exists located adjacent to North Echohawk Way and East Hill Road. Curbs and Gutters: Curbs and gutters which meet Ada County Highway District standards have been constructed abutting the interior streets. Lighting: The applicant will be required to submit plans and details of any proposed parking lot lighting to the City for review and approval by the Design Review Board. Street Names: No new streets are proposed with this application. K. ON AND OFF-SITE PEDESTRIAN/BICYCLE CIRCULATION: Pedestrian Walkways: See discussion under "Sidewalks" above. Bike Paths: None proposed. L. PUBLIC USES PROPOSED: None proposed. M. PUBLIC USES SHOWN ON FUTURE ACQUISITIONS MAP: No map currently exists N. SPECIAL ON-SITE FEATURES: Areas of Critical Environmental Concern — No Evidence of Erosion — No Fish Habitat — No Floodplain — No Mature Trees — Yes — The site contains mature trees located adjacent to the perimeter. Riparian Vegetation — No Steep Slopes — No Stream/Creek — No Unique Animal Life — No Page 4 of 13 K:U'lanning Dept Haglc Applications\SUBS \2017\Piccadilly Village Sub No. 2 ccl ducx Unique Plant Life — Unknown Unstable Soils — Unknown Wildlife Habitat — Unknown Historical Sites — No O. SUMMARY OF REVIEW OF ENVIRONMENTAL ASSESSMENT PLAN: Not required. P. AGENCY RESPONSES: Q. The following agencies have responded and their correspondence is attached to the staff report. Comments, which appear to be of special concern, are noted below: City Engineer: All comments within the Engineer's letters dated December 18, 2017 are of special concern. Director of Parks, Pathways, and Recreation: (Email correspondence dated December 8, 2017): No comment Ada County Highway District Andeavor Central District Health Department Department of Environmental Quality Eagle Fire Department Idaho Transportation Department Sawtooth Law Offices, PLLC (Drainage District #2) LETTERS FROM THE PUBLIC: None received as of this date. STAFF ANALYSIS PROVIDED WITHIN THE STAFF REPORT: A. COMPREHENSIVE PLAN PROVISIONS WHICH ARE OF SPECIAL CONCERN REGARDING THIS PROPOSAL: The Comprehensive Plan Land Use Map (Adopted November 14, 2017), designates this site as the following: Mixed Use Suitable for a mixture of uses including limited office, limited commercial and residential. Residential densities within the designation is up to 20 units per acre but density will be determined on a site to site basis. Uses should complement and not take away from downtown Eagle. Development within this land use designation should be required to proceed through the PUD and/or development agreement process. See the planning area text for a complete description of site specific uses. B. ZONING ORDINANCE PROVISIONS WHICH ARE OF SPECIAL CONCERN REGARDING THIS PROPOSAL: • Eagle City Code Section 8-2-4: Schedule of Building Height and Lot Area Regulations: Minimum Yard Setbacks Note Conditions A To E* Zoning Maximum Front . Interior Street District Height Rear Side Side l MU Minimum Maximum Lot Area Lot (Acres Or Covered F Square And J* Feet) H* Minimum Lot Width I* 35' 20' 20' ' 7.5' 20' 50% 5,000 50' Page 5 of 13 K:\Planning Dept\Gaglc Applicalions\SUBS\201APoccadilly Village Sub No. 2 cd docx C. SUBDIVISION ORDINANCE PROVISIONS WHICH ARE OF SPECIAL CONCERN REGARDING THIS PROPOSAL: • Eagle City Code Section 9-2-3 (B)(1-5) Combining Preliminary and Final Plat in Minor Subdivisions: The applicant may request that the subdivision application be processed as both a preliminary and final plat if all the following exist: 1. The proposed subdivision does not exceed ten (10) lots; 2. No new street dedication or street widening is involved; 3. No major special development considerations are involved such as development in a floodplain, hillside development or the like; 4. All required information for both preliminary and final plat is complete and in an acceptable form; and 5. The proposed subdivision is not in conflict with the Comprehensive Plan or any provision of the Zoning Title of the City. D. DISCUSSION: • Staff has reviewed the particular facts and circumstances of this proposed combined preliminary and final plat and, in terms of Eagle City Code Section 9-2-3(B) "1 thru 5" (minimum criteria to combine a preliminary and final plat), has made the following conclusions: The proposed combined preliminary and final plat: 1. Does not exceed ten (10) lots; 2. No new street dedication or street widening is involved; 3. No major special development considerations are involved such as development in a floodplain, hillside development or the like. 4. All required information for both preliminary and final plat is complete and in an acceptable form; and 5. The proposed subdivision is not in conflict with the Comprehensive Plan or any provision of the Zoning Title of the City. • The overall site development must comply with the requirements of Eagle City Code and the conditions of approval for a Design Review application. • The final plat, date stamped by the city on November 30, 2017, delineates a cross access, shared parking, and public utility and drainage easement located within a portion of three (3) lots shown on the plat. Plat note #3 of the final plat states, "A portion of Lots 21, 22, and 23, Block 1, shall be subject to a common access, shared parking, public utility and drainage easement in favor of Lots 21, 22, and 23, Block 1, as shown on this plat." Although the location of the cross access and easements are delineated on the final plat and noted by plat note #3, the applicant did not provide a cross access/shared parking agreement for the project. The applicant should be required to provide a cross access/shared parking agreement to be reviewed and approved by the City Engineer and staff prior to the City Clerk signing the final plat. Upon approval of the cross access/shared parking agreement, the applicant should record the cross access/shared parking agreement and reference the instrument number on the final plat prior to the issuance of a building permit for the site. Page 6 of 13 K:\I'lanning Dcpt\Nagle Applications\SUBS\ 2017\ Piccadilly Village Sub No. 2 cadmic • The final plat, date stamped by the city on November 30, 2017, shows a five foot (5') utility, drainage, and irrigation easement located adjacent to the southern property line and a ten foot (10') utility, drainage, and irrigation easement located adjacent to North Echohawk Lane. Pursuant to Eagle City Code Section 9-3-6, unobstructed utility and drainage easements, with a minimum total easement width of twelve feet (12'), are required adjacent to front, rear, and side property lines. Since the parking lot area will contain a blanket utility, drainage, and irrigation easement a wider easement will not be required adjacent to the southern property line and North Echohawk Lane. The applicant should provide a revised final plat delineating a 12 - foot wide public utility easement located adjacent to the East Hill Road and State Highway 55 right-of-ways. The revised final plat shall be provided prior to the City Clerk signing the final plat. • The final plat, date stamped by the city on November 30, 2017, does not contain a plat note referencing that the development is subject to the conditions of development associated with the rezone. The applicant should be required to provide a revised final plat with a new plat note stating, "Development of this property shall be in conformance with Eagle City Code or as pursuant to the development agreement associated with RZ-09-00 or any subsequent modifications." The revised final plat should be provided prior to the City Clerk signing the final plat. STAFF RECOMMENDATION PROVIDED WITHIN THE STAFF REPORT: Based upon the information provided to date, staff recommends approval of the requested combined preliminary and final plat with conditions of approval as provided within the staff report. PUBLIC HEARING OF THE COMMISSION: A. A public hearing on the application was held before the Planning and Zoning Commission on January 16, 2018, at which time public testimony was taken and the public hearing was closed. The Commission made their recommendation at that time. B. Oral testimony in favor of the application was presented to the Planning and Zoning Commission by no one (not including the applicant/ representative). C. Oral testimony in opposition to the application was presented to the Planning and Zoning Commission by no one. COMMISSION DELIBERATION: (Granicus time 56:19) Upon closing the public hearing, the Commission discussed during deliberation that: • They appreciated the fact that the applicant worked closely with the adjacent neighbors. • A concern that ITD did not have any comments regarding the application due to the property's close proximity to SH -55. • It is good this commercial area is finally being developed since it has been vacant for so many years. COMMISSION DECISION: The Commission voted 4 to 0 (Koellisch absent) to recommend approval of PP/FP-03-17 for a combined preliminary /final plat for Piccadilly Village Subdivision No. 2 for Old Town I, LLC, with the site specific conditions of approval and standard conditions of approval provided within their findings of fact and conclusions of law document, dated February 5, 2018. Page 7 of 13 K:Wlanning Dept \Eagle Applications\SUBS \201APiccadtlly Village Sub No. 2 ccf.docx PUBLIC HEARING OF THE COUNCIL: A. A public hearing on the application was held before the City Council on February 13, 2018, at which time testimony was taken and the public hearing was closed. The Council made their decision at that time. B. Oral testimony in opposition to the application was presented to the City Council by no one. C. Oral testimony in favor of the application was presented to the City Council by no one (other than the applicant/representative). COUNCIL DECISION: The Council voted 4 to 0 to approve PP/FP-03-17 for a combined preliminary/final plat for Piccadilly Village Subdivision No. 2 (Exhibit "A") for Old Town I, LLC, with the following Planning and Zoning Commission recommended site specific conditions of approval and standard conditions of approval: SITE SPECIFIC CONDITIONS OF APPROVAL: 1. Comply with all conditions within the development agreement for rezone application RZ-09-00 and any subsequent modifications. 2. Comply with all requirements of the City Engineer. 3. The applicant shall submit payment to the City for all engineering and legal fees incurred for reviewing this project, prior to the City Clerk signing the final plat and/or upon receipt of an invoice by the City, whichever occurs first. 4. Provide a cross access/shared parking agreement to be reviewed and approved by the City Engineer and staff prior to the City Clerk signing the final plat. Upon approval of the cross access/shared parking agreement, the applicant shall record the cross access/shared parking agreement and reference the instrument number on the final plat prior to the issuance of a building permit for the site. 5. Provide a revised final plat delineating a 12 -foot wide public utility easement located adjacent to the East Hill Road and State Highway 55 right-of-ways. The revised final plat shall be provided prior to the City Clerk signing the final plat. 6. Provide a revised final plat with a new plat note that states, "Development of this property shall be in conformance with Eagle City Code or as pursuant to the development agreement associated with RZ- 09-00 or any subsequent modifications." The revised final plat shall be provided prior to the City Clerk signing the final plat. 7. Provide a copy of the CC&Rs with language stating that the landscaping, lighting, parking lot, and other shared site improvements are to be maintained by one business owner's association. The CC&Rs shall be reviewed and approved by the City Attorney and staff prior to the City Clerk signing the final plat. 8. The applicant shall take care to locate and protect from damage existing utilities, pipelines and similar structures. Documentation indicating that "Digline" has performed an inspection of the site shall be submitted prior to the issuance of any building permits for the site. 9. All overhead utilities on the site shall be removed and/or placed underground prior to the City Clerk signing the final plat. Page 8 of 13 K:\Planning DernTagle Applications\ SUBS\2017U'iccaddly Village Sub Nu 2 ccl:docx NOTE: In the event a Standard Condition of Approval conflicts with a Site Specific Condition of Approval contained herein the Site Specific Condition of Approval shall control. STANDARD CONDITIONS OF APPROVAL: 1. The applicant shall comply with all requirements of the Ada County Highway District and/or the Idaho Transportation Department, including but not limited to approval of the drainage system, curbs, gutters, streets and sidewalks. 2. Correct street names, as approved by the Ada County Street Name Committee, shall be placed on the plat prior to the City Engineer signing the final plat. 3. Complete water and sewer system construction plans shall be reviewed and approved by the City Engineer. Required improvements shall include, but not be limited to, extending all utilities to the platted property. The developer may submit a letter in lieu of plans explaining why plans may not be necessary. 4. Idaho Department of Health & Welfare approval of the sewer and water facilities is required prior to the City Engineer signing the final plat (I.C. Title 50, Chapter 13 and I.C. 39-118). 5. Written approval of all well water for any shared or commercial well shall be obtained from the Idaho Department of Water Resources prior to the City Engineer signing the final plat. 6. Unless septic tanks are permitted, wet line sewers will be required and the applicant will be required to furnish the City Engineer with a letter from the sewer entity serving the property, accepting the project for service, prior to the City Engineer signing the final plat. 7. All homes being constructed with individual septic systems shall have the septic systems placed on the street side of the home or shall have their sewer drainage system designed with a stub at the house front to allow for future connection to a public sewer system. 8. Per Idaho Code, Section 31-3805, concerning irrigation rights, transfer and disclosure, the water rights appurtenant to the lands in said subdivision which are within the irrigation entity will be transferred from said lands by the owner thereof; or the subdivider shall provide for underground tile or other like satisfactory underground conduit to permit the delivery of water to those landowners within the subdivision who are also within the irrigation entity. See Eagle City Code Section 9-4-1-9(C), which provides overriding and additional specific criteria for pressurized irrigation facilities. Plans showing the delivery system must be approved by a registered professional engineer and shall be approved by the City Engineer prior to the City Engineer signing the final plat. 9. The applicant shall submit a letter from the appropriate drainage entity approving the drainage system and/or accepting said drainage; or submit a letter from a registered professional engineer certifying that all drainage shall be retained on-site prior to the City Engineer signing the final plat. A copy of the construction drawing(s) shall be submitted with the letter. 10. Drainage system plans shall be submitted to the City Engineer for review and approval prior to the City Engineer signing the final plat. The plans shall show how swales, or drain piping, will be developed in the drainage easements. The approved drainage system shall be constructed, or a performance bond shall be submitted to the City Clerk, prior to the City Engineer signing the final plat. The CC&Rs shall contain clauses to be reviewed and approved by the City Engineer and City Attorney, prior to the City Engineer signing the final plat, requiring that lots be so graded that all runoff runs either over the curb, or to the drainage easement, and that no runoff shall cross any lot line onto another lot except within a drainage easement. Page 9 of 13 K:\t'lanning DepQGagle Applications\SUBS \2017Wiccaddly Village Sub No. 2 ca.docx 1 1. No ditch, pipe or other structure, or canal, or drain, for irrigation water or irrigation waste water owned by an organized irrigation district, canal company, ditch association, drainage district, drainage entity, or other irrigation entity, shall be obstructed, routed, covered or changed in any way unless such obstruction, rerouting, covering or changing has first been approved in writing by the entity. A Registered Engineer shall certify that any ditch rerouting, piping, covering or otherwise changing the existing irrigation or waste ditch (1) has been made in such a manner that the flow of water will not be impeded or increased beyond carrying capacity of the downstream ditch; (2) will not otherwise injure any person or persons using or interested in such ditch or their property; and (3) satisfied the Idaho Standards for Public Works Construction. A copy of such written approval and certification shall be filed with the construction drawing and submitted to the City Engineer prior to the City Engineer signing the final plat. 12. Encroachments including, but not limited to, landscaping, fencing, lighting, and/or pathways shall not be located within any easement or right-of-way for any ditch, pipe or other structure, or canal, or drain, used for irrigation water or irrigation waste water without the express written approval of the organized irrigation district, canal company, ditch association, drainage district, drainage entity or other irrigation entity associated with such ditch, pipe or other structure, drainage or canal. The applicant shall submit a copy of the written approval from the irrigation entity, drainage district, or drainage entity prior to the City Clerk signing the final plat. 13. Street light plans shall be submitted and approved as to the location, height and wattage to the City Engineer prior to the City Engineer signing the final plat. All construction shall comply with the City's specifications and standards. The applicant shall delineate on the face of the final plat an easement, acceptable to the City Engineer, for the purpose of installing and maintaining street light fixtures, conduit and wiring lying outside any dedicated public right-of-way, prior to the City Engineer signing the final plat. Whether located inside or outside of the public right-of-way the perpetual maintenance of the street lights shall be the responsibility of the applicant, subdivider, business owner, homeowner, or homeowner's/business owner's association, whichever the case may be. The applicant shall pay applicable street light inspection fees on the proposed subdivision prior to signing of the final plat by the Eagle City Engineer. 14. The applicant shall submit cut sheets showing street lighting details for review and approval by the Zoning Administrator prior to the submittal of the final plat. The plans shall show how the streetlights will facilitate the "Dark Sky" concept of lighting. 15. The applicant shall provide utility easements as required by the public utility providing service, and as may be required by the Eagle City Code, prior to the City Engineer signing the final plat. 16. An approval letter from the Eagle Fire Department shall be submitted to the City prior to the City Engineer signing the final plat. The letter shall include the following comments and minimum requirements, and any other items of concern as may be determined by the Eagle Fire Department officials: a. The applicant has made arrangements to comply with all requirements of the Fire Department. b. The proposed fire hydrant locations shall be reviewed and be approved in writing by the Eagle Fire Department prior to the City Engineer signing the final plat. c. Minimum flow per hydrant shall be 1,000 gallons per minute for one and two family dwellings, 1,500 gallons per minute for dwellings having a fire area in excess of 3,600 square feet, and 1,500 gallons per minute (i.e.; Commercial, Industrial, Schools, etc.). Flow rates shall be inspected in accordance with all agencies having jurisdiction, and shall Page 10 of 13 K:\t'lanning DeptLGagle Applications\SUBS \20ITPiccadilly Village Sub No. 2 ccrducx be verified in writing by the Eagle Fire Department prior to issuance of any building permits. d. The proposed fire protection system shall be reviewed and approved by the Eagle Fire Department prior to issuance of a building permit. 17, Covenants, homeowner's association by-laws or other similar deed restrictions, acceptable to the Eagle City Attorney which provide for the use, control and mutual maintenance of all common areas, storage facilities, recreational facilities, street lights or open spaces shall be reviewed and approved by the Eagle City Attorney prior to the City Engineer signing the final plat. A restrictive covenant must be recorded and a note on the face of the final plat is required, providing for mutual maintenance and access easements. Appropriate papers describing decision-making procedures relating to the maintenance of structures, grounds and parking areas shall be reviewed and approved by the Eagle City Attorney prior to the City Engineer signing the final plat. 18. Should the homeowner's association be responsible for the operation and maintenance of the storm drainage facilities, the covenants and restrictions, homeowner's association by-laws or other similar deed restrictions acceptable to the Eagle City Attorney shall be reviewed and approved by the Eagle City Attorney prior to the City Engineer signing the final plat. 19. The applicant shall submit an application for Design Review, and shall obtain approval for all required landscaping, common area and subdivision signage prior to the City Engineer signing the final plat. 20. Any recreation area, greenbelt area or pathway area along the Boise River, Dry Creek or any other area designated by the City Council or Eagle City Pathway/Greenbelt Committee for a path or walkway shall be approved in writing by the Eagle City Pathway/Greenbelt Committee prior to approval of the final plat by the City Council. 21. Conservation, recreation and river access easements (if applicable) shall be approved by staff and the City Engineer and shall be shown on the final plat prior to approval of the final plat by the City Council. 22. The applicant shall place a note on the face of the plat which states: "Minimum building setback lines shall be in accordance with the applicable zoning and subdivision regulations at the time of issuance of the building permit or as specifically approved and/or required". 23. The applicant shall comply with the provisions of the Eagle City Code, pertaining to floodplain and river protection regulations (if applicable) prior to the City Engineer signing the final plat. 24. The development shall comply with the Boise River Plan (if applicable) in effect at the time of City Council consideration of the final plat. 25. The applicant shall obtain written approval of the development relative to the effects of the Boise River Flood Plain (if applicable) from the Corps of Engineers prior to approval of the final plat by the City Engineer. 26. The applicant shall obtain approval of the development relative to its effects on wetlands or other natural waterways (if applicable) from the Corps of Engineers and the Idaho Department of Water Resources and/or any other agency having jurisdiction prior to the City Engineer signing the final plat. 27. Basements in homes in the flood plain are prohibited. 28. The Americans with Disabilities Act, Uniform Building Code, Eagle City Code, Eagle Comprehensive Plan, and all applicable County, State and Federal Codes and Regulations shall be Page 11 of 13 K:\I'lanning DcpI Fagle Applications\SUBS1201APiccadilly Village Sub No 2 cel docx complied with. All design and construction shall be in accordance with all applicable City of Eagle Codes unless specifically approved by the Commission and/or Council. 29. Any changes to the plans and specifications upon which this approval is based, other than those required by the above conditions, will require submittal of an application for modification and approval of that application prior to commencing any change. Any change by the applicant in the planned use of the property which is the subject of this application, shall require the applicant to comply with all rules, regulations, ordinances, plans, or other regulatory and legal restrictions in force at the time the applicant or its successors in interest submits application to the City of Eagle for a change to the planned use of the subject property. 30. No public board, agency, commission, official or other authority shall proceed with the construction of or authorize the construction of any of the public improvements required by the Eagle City Code Title 9 "Land Subdivisions" until the final plat has received the approval of the City Council (ECC 9-6-5 (A) (2)). After Council approval of the final plat, the applicant may construct any approved improvements before the City Engineer signs the final plat. The applicant shall provide a financial guarantee of performance in the amount of 150% of the total estimated cost for completing any required improvements (see resolution 98-3) prior to the City Engineer signing the final plat. The financial guarantee shall be a Letter of Credit, Certificate of Deposit, cash deposit or certified check. 31. In accordance with Eagle City Code, failure to obtain a recorded final plat for the subdivision within one year following City Council approval shall cause this approval to be null and void, unless a time extension is granted by the City Council. 32. Prior to submitting the final plat for recording, the following must provide endorsements or certifications: Owners or dedicators, Registered Land Surveyor, County Engineer, Central District Health Department, Ada County Treasurer, Ada County Highway District Commissioners, City Engineer, and City Clerk. 33. The City's actions on the application does not grant the applicant any appropriation of water or interference with existing water rights. The applicant indemnifies and holds the City harmless for any and all water rights, claims in any way associated with this application. 34. The applicant shall take care to locate and protect from damage existing utilities, pipelines and similar structures. Documentation indicating that "Digline" has performed an inspection of the site shall be submitted prior to the issuance of any building permits for the site. 35. Place a note on the final plat which states in general that surrounding land with farm uses and related activities shall be protected pursuant to the Idaho Right to Farm Act. 36. The applicant shall install at the entrance to the subdivision a 4' x 4' plywood or other hard surface sign (mounted on two 4"x 4" posts with the bottom of the sign being a minimum of 3 -feet above the ground) noticing the contractors to clean up daily, no loud music, and no dogs off leash. CONCLUSIONS OF LAW: 1. The Council reviewed the particular facts and circumstances of this proposed combined preliminary/final plat (PP/FP-03-17) and based upon the information provided concludes that the proposed combined preliminary plat/final plat application is in accordance with the City of Eagle Title 9 (Subdivisions) because: a. The subdivision will be harmonious with and in accordance with the general objectives or with any specific objective of the Comprehensive Plan and/or Eagle City Code Title 9, as shown within the findings provided within this document and the proposed use is in accordance with the Mixed Use land use designation of this area shown within the Comprehensive Plan; Page 12 of 13 K:\I'lanning Dept \Eagle Applications\SUBS \2017\ Piccadilly Village Sub No. 2 cel.ducx b. The subdivision will be served adequately by essential public facilities such as streets, police and fire protection, schools, drainage structures, refuse disposal, water and sewer; or that the persons or agencies responsible for the establishment of the proposed use shall be able to provide adequately any such services, as noted in the documentation provided from said agencies and as required as a part of the conditions of approval; c. That there are no known capital improvement programs for which this development would prevent continuity; d. That based upon agency verification of the affected agencies, there is adequate public financial capability to support the proposed development; e. That any health, safety and environmental problems that were brought to the Council's attention have been adequately addressed by the applicant or will be conditions of approval as set forth within the conditions of approval herein. 2. The Council reviewed the particular facts and circumstances of this proposed combined preliminary and final plat (PP/FP-03-17) and, in terms of Eagle City Code Section 9-2-3(B) "1 thru 5" (minimum criteria to combine a preliminary and final plat), has made the following conclusions: The proposed combined preliminary and final plat: 1. Does not exceed ten (10) lots; 2. No new street dedication or street widening is involved; 3. No major special development considerations are involved such as development in a floodplain, hillside development or the like. 4. All required information for both preliminary and final plat is complete and in an acceptable form; and 5. The proposed subdivision is not in conflict with the Comprehensive Plan or any provision of the Zoning Title of the City. DATED this 27th day of February, 2018. CITY COUNCIL OF THE CITY OF EAGLE Ada County, Idaho Stan Ridgeway, Mayor ATTEST: Sharon K. Bergmann, Eagle Ci{y Clerk o•°.� OF EAC<F�'•. ��•• oo vOR4 ' •0� F� •* :v .v•4 • SAL •% S 4i p •�. ••i URPolOkl • S. ,�.00000000oo000000000000000 Page 13 of 13 KAPlanning Dcptlfiagk Applications\SUBS\2017\ Piccadilly Village Sub No. 2 ccl:Jocx z N61'36'24'E 23.50' S81'49'50'E 10.69' I W ''''''''"'''"'"'"""'"'""T PER ����� I CO i I 102056229 3 4 •77. PLAT SHOWING PICCADILLY VILLAGE SUBDIVISION NO.2 RESUBDIVISION OF LOT 14 BLOCK 1 LOCATED IN THE SW Y4 OF THE SE Y4 OF SECTION 10, T.4N., R.1E., B.M., EAGLE, ADA COUNTY, IDAHO §81'49'42-r E. HILL RO. 114..49'20'E 4.64. 34.64' 4436'53'32' 33.69" �1`TO0 1 1 � 11 \ 110.0' I� E. PICCADILLY LN, CURVE TABLE CURVE RADIUS LENGTH CHORD DIST. CHORD ORC. DELTA Cl 13.70 22.06 19.70 N34001'04'W 92'17'06' C2 134.50 105.71 103.01 441422'57'W 45'01'53' C3 75.50 33.43 33.16 02412'21'W 25'2717' 04 20.00 17.67 17.10 N13V6'4B'E 5017'05' 05 24.00 12.98 12.62 442315'421E 30.58'54' 06 75.50 7.67 7.117 S14'30'23'E 5458'22' tt /4S 5' <1W I 400'-I __�� 1=327' RFAL POINT OF BEGINNING SE CORNER OF LOT 14. BLOCK I 1/4 510 1201 sr 515 NO'00'00-E 285 B6' 145007' S10 S11 4499'02'53'W 2651.71' 515 514 BASIS OF BEARING r\L_ur-.:vt,.) 2y 1-ILED CITY OF EAGLE NO p 3 0 iv File: Rot to: JV .111. 1I 1 10 "P 0 w 4n SCALE: 1" = 40' 0 000ND 1/T IRON PIN PIS RELACEO 6811 9/6' IRON F O FOUND 5/8' IRON PIN NO PLACED CAP PL5 7729 O FOUND ALUMINUM CAP 1.10A SET 1/2 IRON PIN 14114 CA • SET 5/6' IRON PIN N11H C PROPERTY BOUNOAR2 LINE LOT LINE RICHT-OF-WAY LINE EASEMENT UNE PER PLAT PICCAOILLY VILLAGE 5UBDP SET BACK LINE PER PLAT PICCADILLY VILLAGE 5LBD1 CROSS ACCESS, SHARED F PUBLIC UI1UTY AND DRAIN /Y2/ .77.7. 0 .108 NO 17 333 'HEFT 1 OF 3 LOT N0. NOO OO UO 4 roO * EASEMENT BEARINGS AND NOTES: 1. ANY RE-SOBOMSION OF 19115 PLAT SNAIL BE IN COMPLIA 114E MOST RECENTLY APPROVED SUBDIVISION STANDARDS 012 00 EAGLE. 2. MINIMUM BUILDING SETBACK LINES SHALL BE IN ACCORDAA APPLICABLE ZONING AND 506011.40ON REG4ILA110N5 AT TH. 155UANCE OF A BUILDING PERMIT OR A5 SPECWICALLY APPRu,,o AND/OR REQUIRED. 3. A PORTON OF 1.015 21. 22 AND 23, BLOCK 1 SHALL BE SUBJECT TO A A COMMON ACCESS. SHARED PARKING. PUBLIC UTILITY AND DRAINAGE EASEMENT IN FAVOR OF LOTS 21. 22 AND 23, BLOCK 1, AS SHOWN ON TH15 PLAT. 4.. THE MAINTENANCE FOR ALL IRRIGATION AND DRAINAGE FACILITIES OUTSIDE 144E PUBUC RIGHT-OF-WAY 15 1110 RESPONSIBILITY OF THE 101 04NER5 1HROUCH W44106 THESE FACILI11E5 PASS. 5, DIRECT VEHICULAR ACCESS TO E .311I1 RD. AND STATE HIGHWAY 55 15 R60 6641E0 UNLESS SPECIFICALLY ALLOWED BY 191E AOA COUNTY HIGHWAY DISTRICT AND THE CITY OF EAGLE. B. 00511NG ACRD PERMANENT EASEMENT INSTRUMENT N0. 102056229. 0412•11. '. IDAHO GP SURVEY S GROUP, LLC 1450 E WATERTOWER ST SUITE 130 MERIDIAN, IDAHO 83642 PH (208) 646.8570 FAX (208)864-5399 11b,i 1WIHX3