Loading...
Building - 173030 - 426 N Edgewood Lane - 08/17/2017 (5)No. 1- 3D O City of Eagle Building Permit Application - Residential THE UNERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS: Contractor Co. Name 4 % %% t-/G/zj/ /!&7Z Contact Name:I f v) JK� ,/o,z7H X Company Address:I 7f/ jy/ 2 - OD City, State, Zip:I /.0 736/6 Structure Type: (Choose one from each row) Home (' Garage FOOTINGS (Concrete r Masonry FOUNDATION pc Concrete r Masonry EXTERIOR 17 Wood ✓ Masonry r Concrete • Vaneer ✓ Metal (' Shed INSULATION ResCheck ✓ Prescriptive BASEMENT IT( Yes ✓ No State License# I C;ivi�� Expiration Date:I Phone:I 995" 7d7' Fax: Addition C Remodel (' Other INTERIOR WALLS X Drywall r Firewall r Other Building Department Information Shaded area to be completed by Building Department 14'2- Value Permit Fee $ Plan Review Fee$ C New C Pool C Patio C' Other ROOF 157 Shingle r Tile r Other Date Home Owner 4 ,N ,' /p,E'7, -/ F-7? Owner Address L/Z�, /j/ el2KGc.102.) c Y City, State, Zip] �/q-z ; /O 6,%(> Owner Phone] CEILING FLOORS HEAT R. Drywall , Wood [Gas r Grid r Concrete r Electric r Other r Other r Other Remarks: /2L A/fT //6)/1 Sq. Ft. - Living Area Sq. Ft. - Basement Sq. Ft. - Garage Sq. Ft. - Porch Mech Review Fee .$ Occupancy Group/Division i"\,-. P&Z Review Fee .. $ GJl > � Zone Dev Impact Fee .. $ ACHD Impact Fee $ Deposit Received .$ j 3-4 L4S 2..:13 IECC Fee $ 5-0c' r_. BP TOTAL DUE ...(fl City of Eagle Water $ LOC.) Total with Water. $ Receipt# CD'2.c1 Type: (�J Building Official City's Date Stamp THIS PERMIT is issued subject to the regulations contained in the 2009 Building Code and Zoning Regulations of the City of Eagle and it is hereby agreed that the work be done as shown in the plans and specifications will be completed in accordance with the regulations pertaining and applicable thereto: APPLICANT IS RESPONSIBLE FOR LOCATION OF ALL PROPERTY LINES AND SET BACKS In 100 Yr Floodplain? C Yes .er No Subdivision: Lot:1 Permit Address:I y(' />/ ZDic.cJC:Q1.) N HOA/ACC Required? ,i No (' Yes Applicant Signatur/ Block: I Lot Sizei 1 City of Eagle Residential Addition Permit Permit Pt: 173030 Property Owner MORTIMER M ALAN Owner Address 710 AQUARIUS WAY Owner City State Zip LA GRANDE OR 97850-0000 Issue Date 8/17/2017 Foundation Only Issue Date Builder NEme Owner/Lessee-Builder Builder Ac.dress Builder Ciy State Zip Builder Te ephone Builder Registration # Subdivision Lot Property A ldress Type Deposit Receipt # Issue Receipt # Sq Ft Living 1998 Sq Ft Porch 0 Eagle Water Development Notes: 4N1E10 Block 426 N EDGEWOOD LN 15.007297 15.008000 SgFtBmnt 0 SgFtGrg 0 Value of Improvement $143327 EM2 Fee Eagle Sewer ACHD Contractor's Printed Name Co ltractor's Signature City Clerk/Authorized Personnel Fees: IECC - Residential Permit Fee Plan Review Fee Residential Plan Review Deposit P&Z Review Fee -Residential Total Fees Less Deposit Less Foundation Only Balance Due //'/(i7eTirtz- '211`c‘-ArN -dalat) Call The -City of Eagle Inspection Line (208) 939-4462 $50.00 $1,236.38 $382.73 $50.00 $50.00 $1,769.11 $50.00 $0.00 Said structure and/or use to conform to specifications and plans submitted and must be in full compliance with ordinances of the City of eagle subject to inspection permits and fees as required. CITY OF EAGLE 660 E. Civic Lane PO BOX 1520 EAGLE ID 83616 (208) 939-6813 Receipt No: 15.007297 Jun 27, 2017 Michael Mortimer Previous Balance: BUILDING PERMITS PLAN REVIEW FEES 426 N Edgewood Ln .00 50.00 Total: 50.00 CREDIT CARD Payor: Michael Mortimer Total Applied: 50.00 50.00 Change Tendered: .00 Duplicate Copy 06/27/2017 2:09 PM VV\o v-i-1 • c°15- 3018 Res Check Approved 2012 RES CHECK Footing Approved Foundation Crawl Space Approved Foundation Vents Ventilation Floodplain N/A Venting Positive Approved Comply to R401.3 Drainage Wall Approved Engineered Construction Tall Wall Elm N/A Egress Approved Insulation Approved 2012 Res Check Roof Approved Residential Approval Form Building Permit # 173030 Date: 8/15/2017 Subdivision: Not Applicable Lot: Block: Floodplain: Address: 426 N Edgewood Ln Lot Size: 1.17 Lot SF: 50,965 Zone: R-4 Water : Waste: HOA: BP Type: Residential Addition OW Building - Specifications Fire Sprinkler System Yes o No Setbacks - Front N/A - Back Approved 25' 114' - Side Approved 7.5' 33.5' - Side Approved 7.5' 56.5' P&Z - Snecifications - Misc N/A Easements N/A Building Height % Lot Coverage Architectural Style Tree Reauirements Elevation Certificate Minimum Rea Proposed Maximum Rg Proposed Approved 25' 24' Approved 40% 8.7`A, N/A N/A N/A Building Dept. Comments: P&Z Dept. Comments: With Unfinished Storage 'Status: repared by: Date: APPROVED rian Parker 08/07/2017 City of Eagle Plumbing Permit 660 E. Civic Lane Eagle, ID 83616 Phone: (208) 489-8760 -- Inspection Line: (208) 939-4462 Permit Number 180178 I PLUMBER Owner/Lessee-Builder Issue Date 1/9/2018 Issue Receipt 22.000673 Registration #: I PERMIT ADDRESS roperty Owner: MORTIMER M ALAN Subdivision: 4N lE 10 Lot Block ddress 426 N EDGEWOOD LN IRESIDENTIAL PERMIT FEES Plumbing New Homes Job Scope / Notes Contractor's Printed Name Contractor's Signature $195.00 Total Fee: $195.00 City Clerk/Authorized Personnel New Home Plumbing Permit Application City of Eagle Building Department 660 E Civic Lane Eagle, ID 83616 Phone: (208) 489-8760 Fax: (208) 489-8767 Email: mthurston@cityofeagle.org or slopez@cityofeagle.org Plumbing Contractor Information Company: Contact Name: Contact Phone: Address,City, Zip License # /Wel NaTi!V7 Zmd `/c)q 076 Z-712--W0CD Lit/ Expiration: New Home Plumbing Permit Requested For: Address: Subdivision: No. I�S�11�i Submit by Email 1 Job Location 4/Z /Ve E7)(5C wC l) 1/ Lot: Block: Owner/Builder's Name: I ��i(F ! ae. l" `�) Owner/BuilderAddress:1 10 %V ni-FAITID C 1V Enter '1' in the appropriate Square Footage of Living Area (Exception is home over 4500 sf) Fee <= 1500 square feet home 1501 to 2500 square feet home 2501 to 3500 square feet hom 3501 to 4500 square feet hom Greater than 4500 square feet home ($325 + $65 x # of additional 1000 sqft or portion thereof), Total New Home Plumbing Permit Fee: Notes Permit will be issued when paid in full via Check, Cash, or Credit Card (all Credit Card Payments are subject to a non-refundable Portal Admin Fee of 30/0 plus $1.00) Choose Payment Method: C Pay On -Line (Link on Home Page) (' Check/Cash How do you prefer to receive the 'New Home Plumbing Permit' - fill in the appropriate box below Fax# I Ready for Inspection? (' No (Next working day) Email I F1 /& e /`-1, 71ber C ofv1 (' Yes Type of Inspection' Pick up Hard Copy at Building Department Inspections are Monday thru Friday I certify that the inf rmatipn c ntained herein is complete and accurate to the best of my knowledge Signature: I // I Date: I // k// 8 THIS PERMIT is issu d subject to the regulations contained in the 2012 Building and Plumbing Codes and Zoning Regulations of the City of Eagle and it is hereby agreed that the work be done as shown in the plans and specifications will be completed in accordance with the regulations pertaining and applicable thereto. Permit Number 180179 I HVAC CONTRACTOR Owner/Lessee-Builder Registration #: PERMIT ADDRESS Property Owner: MORTIMER M ALAN Subdivision: 4N lE 10 Lot Block Address 426 N EDGEWOOD LN RESIDENTIAL PERMIT FEES Job Scope / Notes City of Eagle Mechanical Permit 660 E. Civic Lane Eagle, ID 83616 Inspection Line: (208) 939-4462 Issue Date 1/9/2018 Issue Receipt 22.000673 Total Fee: $0.00 Contractor's Printed Name Contractor's Signature City Clerk/Authorized Personnel d/k- Mie/---//k-/?-R 1/L� New Home Mechanical Permit Application City of Eagle Building Department 660 E Civic Lane Eagle, ID 83616 Phone: (208) 489-8760 Fax: (208) 489-8767 Email: mmaring@cityofeagle.org or slopez@cityofeagle.org HVAC Contractor Information Company: Contact Name: "4l16 /�'fl647-7) ll--i? Contact Phone: 1 Address,City, Zip License # Expiration: New Home Mechanical Permit Requested For: Address: Subdivision: No. I ?s V I f Job Location Print Form 4/a A). t�fo�cvi5 Lot: Block: Owner/Builder's Name: "11k itaWill&' Owner/Builder Address: Enter '1' in the appropriate Square Footage of Living Area (Exception is home over 4500 sf) Fee < = 1500 square feet home 1501 to 2500 square feet home 2501 to 3500 square feet home 3501 to 4500 square feet home Greater than 4500 square feet home ($325 + $65 x # of additional 1000 sqft or portion thereof) Total New Home Mechanical Permit Fee: ,IZowcv bk.) Notes Permit will be issued when paid in full via Check, Cash, or Credit Card (all Credit Card Payments are subject to a non-refundable Portal Admin Fee of 3% plus $1.00) Choose Payment Method: C Pay On -Line (Link on Home Page) (' Check/Cash How do you prefer to receive the 'New Home Mechanical Permit' - fill in the appropriate box below Fax # Ready for Inspection? ZkNo (Next working day) , Signature: Email I mike (' Yes Type of Inspection Pick up Hard Copy at ❑ Building Department (Inspections are Monday thru Friday Date: th1/28 THIS PERMIT is issued subject to the regulations contained in the 2009 Building and Mechanical Codes and Zoning Regulations of the City of Eagle and it is hereby agreed that the work be done as shown in the plans and specifications will be completed in accordance with the regulations pertaining and applicable thereto. -- wrightsoft Manual S Compliance Report Entire House Idaho HVAC Design LLC ID Phone 989-0098 Email. Geoff@IdahoHVAC com Web www IdahoHVACDesign com For: Design Conditions Outdoor design DB: 95.0°F Outdoor design WB: 63.1 °F Indoor design DB: 75.0°F Indoor RH: 50% MORTIMER ADDITION, 426 N EDGEWOOD, EAGLE Cooling Equipment Sensible gain: 18800 Latent gain: 0 Total gain: 18800 Estimated airflow: 870 Btuh Btuh Btuh cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: Bryant Actual airflow: 870 Sensible capacity: 20905 Latent capacity: 811 Total capacity: 21716 cfm Btuh Btuh Btuh Job: Date: 02/27/2017 By: Entering coil DB: 78.4°F Entering coil WB: 62.6°F Model: 113ANA0240NOODO+C N PVP3017ALA++TDR 111% of load 0% of load 116% of load SHR: 96% Heating Equipment Design Conditions Outdoor design DB: 10.5°F Indoor design DB: 70.0°F Heat loss: 32820 Btuh Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: Bryant Actual airflow 790 cfm Output capacity: 39000 Btuh Model: 915SA36040S 17A-A 119% of load Meets are all requirements of ACCA Manual S. 41- wrightsoft Right -Suite® Universal 2017 17.0 16 RSU14545 ACCK MORTIMER ADDITION - dave\MORTIMER ADDITION.rup Calc = MJ8 Front Door faces. N Entering coil DB: 62.4°F Temp. rise: 50 °F 2017-Mar-02 14.14 29 Page 1 +- wrightsoft Load Short Form Entire House Idaho HVAC Design LLC ID Phone 989-0098 Email GeoffraIdahoHVAC.com Web www IdahoHVACDesign com For: lill " i s• nW MORTIMER ADDITION, 426 N EDGEWOOD, EAGLE Job: Date: 02/27/2017 By: Design Information Outside db (°F) Inside db (°F) Design TD (°F) Daily range Inside humidity (%) Moisture difference (gr/Ib) I , 1 Htg 11 70 60 50 52 CIg 95 75 20 H 50 -27 Method Construction quality Fireplaces u. i 1 1,0 i Y7111 .nil HEATING EQUIPMENT Make Bryant Trade Bryant 915 Legacy Line 95 Gas ... Model 915SA36040S17A-A AHRI ref 5584119 Efficiency 95.5 AFUE Heating input 40000 Btuh Heating output 39000 Btuh Temperature rise 50 °F Actual air flow 790 cfm Air flow factor 0.028 cfm/Btuh Static pressure 0.70 in H2O Space thermostat ROOM NAME BASEMENT GREAT RM/KITCHEN BH MASTER BH MASTER BD MASTER WIC LAUNDRY/MUD RM Area (ft2) 697 777 72 161 172 114 231 Htg load (Btuh) Infiltration Simplified Semi -tight II 0 COOLING EQUIPMENT Make Bryant Trade BRYANT HEATING AND COOLING SYS... Cond 113ANA0240NOODO Coil CNPVP3017ALA++TDR AHRI ref 9397976 Efficiency 11.0 EER, 13 SEER Sensible cooling 19720 Btuh Latent cooling 3480 Btuh Total cooling 23200 Btuh Actual air flow 870 cfm Air flow factor 0.051 cfm/Btuh Static pressure 0.70 in H2O Load sensible heat ratio 1.00 5940 10848 0 1890 2361 2189 4773 CIg load (Btuh) 575 10712 0 972 1519 607 2795 Htg AVF CIg AVF (cfm) (cfm) 168 306 0 53 67 62 135 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft'" Right -Suite® Universal 2017 17.0 16 RSU14545 ACD. MORTIMER ADDITION - davelMORTIMER ADDITION rup Calc = MJ8 Front Door faces. N 29 542 0 49 77 31 142 2017-Mar-02 14:14-29 Page 1 Entire House d 2224 28002 17180 790 870 Other equip Toads 4818 1620 Equip. @ 1.00 RSM 18800 Latent cooling 0 TOTALS 2224 32820 18800 790 870 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. —141— wrightsoft Right-Suitee Universal 2017 17.0.16 RSU14545 ACCik ... MORTIMER ADDITION - daveeMORTIMER ADDITION.rup Calc = MJ8 Front Door faces: N 2017-Mar-02 14:14:29 Page 2 Building Analysis 4i- wrightsoft Entire House Idaho HVAC Design LLC ID Phone: 989-0098 Email. Geoff@IdahoHVAC corn Web www IdahoHVACDesign corn For: Pro'ect Information MORTIMER ADDITION, 426 N EDGEWOOD, EAGLE Job: Date: 02/27/2017 By: Desi • n Conditions Location: Boise Air Terminal, ID, US Elevation: 2867 ft Latitude: 44°N Outdoor: Dry bulb (°F) Daily range (°F) Wet bulb (°F) Wind speed (mph) Heating 11 15.0 Cooling 95 30 (H ) 63 7.5 Indoor: Indoor temperature (°F) Design TD (°F) Relative humidity (%) Moisture difference (gr/lb) Infiltration: Method Construction quality Fireplaces Heatin • Component Btuhlft2 Btuh % of load Walls 3.8 8838 26.9 Glazing 20.8 4915 15.0 Doors 21.2 892 2.7 Ceilings 1.5 2363 7.2 Floors 1.7 2643 8.1 Infiltration 2.0 3678 11.2 Ducts 4672 14.2 Piping 0 0 Humidification 0 0 Ventilation 4818 14.7 Adjustments 0 Total 32820 100.0 Component Walls Glazing Doors Ceilings Floors Infiltration Ducts Ventilation Internal gains Blower Adjustments Total Coolin • Btuh/ft2 Btuh % of load 0.7 1559 8.3 26.4 6237 33.2 9.5 397 2.1 1.3 1986 10.6 0.2 291 1.5 0.3 618 3.3 3032 16.1 1620 8.6 3060 16.3 0 0 0 18800 100.0 Latent Cooling Load = 0 Btuh Overall U-value = 0.057 Btuh/ft2-°F Data entries checked. Walls Glazing Glazing +}+. wrightsoft- Right -Suite Universal 2017 17.016 RSU14545 , CA MORTIMER ADDITION - dave\MORTIMER ADDITION run Calc = MJ8 Front Door faces' N Doors Ceilings Walls Doors Ceilings Heating Cooling 70 75 60 20 50 50 52.5 -26.9 Simplified Semi -tight 0 Ventilation Ducts Infiltration Floors Ventilation Internal Gains Ducts Infiltration Other 2017-Mar-02 14.14 29 Page 1 r-13 cav ins, 8" thk, 1/2" gypsum board int fnsh Partitions (none) Windows 10D-f: 2 glazing, clr low-e outr, air gas, insulated fiberglass frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.35); 1 ft overhang (7 ft window ht, 2 ft sep.); 6.67 ft head ht Low-E Vinyl Frame Window 35 U 35 SHGC: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.35); 1 ft overhang (1 ft window ht, 2 ft sep.); 6.67 ft head ht Low-E Vinyl Frame Window 35 U 35 SHGC: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.35); 1 ft overhang (5 ft window ht, 2 ft sep.); 6.67 ft head ht Low-E Vinyl Frame Window 35 U 35 SHGC: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.35); 1 ft overhang (5.5 ft window ht, 2 ft sep.); 6.67 ft head ht Low-E Vinyl Frame Window 35 U 35 SHGC: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.35); 1 ft overhang (4 ft window ht, 2 ft sep.); 6.67 ft head ht +i wrightsoft Component Constructions Entire House Idaho HVAC Design LLC ID Phone. 989-0098 Email Geotf@IdahoHVAC com Web. www.IdahoHVACDesign com Job: Date: 02/27/2017 By: Project Information For: MORTIMER ADDITION, 426 N EDGEWOOD, EAGLE Design Conditions Location: Boise Air Terminal, ID, US Elevation: 2867 ft Latitude: 44°N Outdoor: Dry bulb (°F) Daily range (°F) Wet bulb (°F) Wind speed (mph) Construction descriptions Heating 11 15.0 Cooling 95 30 (H ) 63 7.5 Walls 12F-Osw: Frmwall, wd ext, 1/2" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Indoor: Indoor temperature (°F) Design TD (°F) Relative humidity (%) Moisture difference (gr/Ib) Infiltration: Method Construction quality Fireplaces Or Area ft' n e s w all 15B13-0wc-6: Bg wall, light dry soil. 2"x4" wood int frm, concrete wall, n e s w all n e all n w all n s all n e all e Heating Cooling 70 75 60 20 50 50 52.5 -26.9 Simplified Semi -tight 0 . n i.0 dl u 11 U-value Insul R Htg HTM Loss Clg HTM Gain Btuh/ft'-°F ft'-"F/Btuh Btuh4Ft` Btuh Btuh/ft' Btuh 310 0.065 21.0 3.87 1200 0.99 308 272 0.065 21.0 3.87 1050 0.99 270 362 0.065 21.0 3.87 1399 0.99 360 363 0.065 21.0 3.87 1404 0.99 361 1306 0.065 21.0 3.87 5052 0.99 1299 161 0.053 13.0 3.81 612 0.27 44 330 0.053 13.0 3.71 1223 0.23 75 161 0.053 13.0 3.81 612 0.27 44 351 0.053 13.0 3.81 1339 0.27 96 1002 0.053 13.0 3.78 3786 0.26 259 21 0.350 0 20.8 437 9.55 201 35 0.350 0 20.8 729 27.8 974 56 0.350 0 20.8 1166 21.0 1174 3 0.350 0 20.8 62 13.6 41 6 0.350 0 20.8 125 39.7 238 9 0.350 0 20.8 187 31.0 279 30 0.350 0 20.8 625 13.6 409 30 0.350 0 20.8 625 22.7 680 60 0.350 0 20.8 1249 18.2 1090 28 0.350 0 20.8 573 13.6 375 28 0 350 0 20.8 573 39.7 1093 55 0.350 0 20.8 1145 26.7 1468 20 0.350 0 20.8 416 39.7 795 wrightsoft- Right-Surtee Universal 2017 17 0 16 RSU14545 ACCA .. MORTIMER ADDITION - davelMORTIMER ADDITION rup Cale = MJ8 Front Door faces. N 2017-Mar-02 14 14 29 Page 1 Low-E Vinyl Frame Window 35 U 35 SHGC: 2 glazing, clr low-e outr, e 36 0.350 0 20.8 750 39.7 1431 air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" thk; NFRC rated (SHGC=0.35); 1 ft overhang (6 ft window ht, 2 ft sep.); 6.67 ft head ht Doors R 2-8 U 357: Door, wd sc type e 21 0.357 2.8 21.2 446 9.46 199 w 21 0.357 2.8 21.2 446 9.46 199 all 42 0.357 2.8 21.2 892 9.46 397 Ceilings 16B-38ad: Attic ceiling, asphalt shingles roof mat, r-38 ceil ins, 1/2" 1528 0.026 38.0 1.55 2363 1.30 1986 gypsum board int fnsh Floors 20P-30c: Fir floor, frm flr, 12" thkns, carpet fir fnsh, r-30 cav ins, amb 832 0.035 30.0 2.08 1733 0.35 291 ovr 21A-28t: Bg floor, light dry soil, 6.5' depth 696 0.022 0 1.31 910 0 0 wrightsoft" Right -Suite® Universal 2017 17.0.16 RSU14545 ACG ... MORTIMER ADDITION - dave\MORTIMER ADDITION.rup Calc = MJ8 Front Door faces: N 2017-Mar-02 14:14:29 Page 2 wrightsoft ' Project Summary Entire House Idaho HVAC Design LLC ID Phone 989-0098 Email: Geoff@IdahoHVAC.com Web. www IdahoHVACDesign.com Pro'ect Information For: MORTIMER ADDITION, 426 N EDGEWOOD, EAGLE Notes: See disclaimer for additional information. Job: Date: 02/27/2017 By: Desi n Information Weather: Boise Air Terminal, ID, US Winter Design Conditions Outside db Inside db Design TD 11 °F 70 °F 60 °F Summer Design Conditions Outside db Inside db Design TD Daily range Relative humidity Moisture difference 95 °F 75 °F 20 °F H 50 % -27 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 23330 Btuh Structure 14149 Btuh Ducts 4672 Btuh Ducts 3032 Btuh Central vent (82 cfm) 4818 Btuh Central vent (82 cfm) 1620 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32820 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 18800 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure -114 Btuh Ducts -131 Btuh Central vent (82 cfm) -1346 Btuh Heating Cooling Outside air Area (ft2) 2224 2224 Equipment latent load 0 Btuh Volume (ft3) 17017 17017 Air changes/hour 0 22 0.11 Equipment total load 18800 Btuh Equiv. AVF (cfm) 62 31 Req. total capacity at 0.85 SHR 1 8 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade Bryant 915 Legacy Line 95 Gas ... Trade BRYANT HEATING AND COOLING SYS... Model 915SA36040S17A-A Cond 113ANA0240N00D0 AHRI ref 5584119 Coil CNPVP3017ALA++TDR AHRI ref 9397976 Efficiency 95.5 AFUE Efficiency 11.0 EER, 13 SEER Heating input 40000 Btuh Sensible cooling 19720 Btuh Heating output 39000 Btuh Latent cooling 3480 Btuh Temperature rise 50 °F Total cooling 23200 Btuh Actual air flow 790 cfm Actual air flow 870 cfm Air flow factor 0.028 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 41- wrightsoft Right-Sulteo Universal 2017 17.016 RSU14545 AFE k MORTIMER ADDITION - davelMORTIMER ADDITION rup Calc = MJ8 Front Door faces N 2017-Mar-02 14.14.29 Page 1 +1# wrightsoft AED Assessment Entire House Idaho HVAC Design LLC ID Phone' 989-0098 Email Geoff@ldahoHVAC com Web www.IdahoHVACDesign com Job: Date: 02/27/2017 By: Project Information For: MORTIMER ADDITION, 426 N EDGEWOOD, EAGLE Design Conditions Location: Boise Air Terminal, ID, US Elevation: 2867 ft Latitude: 44°N Outdoor: Dry bulb (°F) Daily range (°F) Wet bulb (°F) Wind speed (mph) Heating 11 15.0 Indoor: Indoor temperature (°F) Design TD (°F) Relative humidity (%) Cooling Moisture difference (gr/Ib) 95 Infiltration: 30 (H ) 63 7.5 Heating Cooling 70 75 60 20 50 50 52.5 -26.9 Test for Adequate Exposure Diversity 9,000— 8.000-- 7.000— 6.000 f 5.000-- - 3 3.0001 2,000- 1,000- 0 { 10 Hourly Glazing Load 17. 73 Mar ar 14 i 15 16 17 18 Maximum hourly glazing load exceeds average by 18.7%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh " 1 - wrightsoft Right -Suite® Universal 2017 17.0 16 RSU14545 ACCA . MORTIMER ADDITION - dave\MORTIMER ADDITION rup Calc = MJ8 Front Door faces. N 19 20 2017-Mar-02 14' 14.29 Page 1 wrightsoft Right-J® Worksheet Entire House Idaho HVAC Design LLC ID Phone: 989-0098 Email: Geoff@ldahoHVAC.com Web: www.IdahoHVACDesign.com 1 Room name 2 Exposed wall 3 Room height 4 Room dimensions 5 Room area 9.7 ft 2224.5 ft' Job: Date: 02/27/2017 By: Entire House BASEMENT 270.0 ft 113.7 ft d 9.0 ft heat/cool 17.8 x 39.1 ft 697.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft? °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12F-0sw 0.065 n 3.87 0.99 392 310 1200 308 0 0 0 0 --G 10D-f 0.350 n 20.82 9.55 21 0 437 201 0 0 0 0 -G Law-E Vinyl Frame Wi 0.350 n 20.82 13.64 3 0 62 41 0 0 0 0 -G Low-E Vinyl Frame Wi 0.350 n 20.82 13.64 30 0 625 409 0 0 0 0 11 -G Law-E Vinyl Frame Wi 0.350 n 20.82 13.64 28 0 573 375 0 0 0 0 W 15813-Owc-6 0.093 n 3.81 0.27 161 161 612 44 161 161 612 44 W 12F-Qsw 0.065 e 3.87 0.99 390 272 1050 270 0 0 0 0 -G 10D-f 0.350 e 20.82 27.82 35 0 729 974 0 0 0 0 - (' Law-E Vinyl Frame Wi 0.350 e 20.82 39.75 20 0 416 795 0 0 0 0 --.G Low-E Vinyl Frame Wi 0.350 e 20.82 39.75 28 0 573 1093 0 0 0 0 -G Low-E Vinyl Frame Wi 0.350 e 20.82 39.75 36 0 750 1431 0 0 0 0 Val 15813-Owc-6 0.093 e 3.71 0.23 351 330 1223 75 351 330 1223 75 l---D R 2-8 U 357 0.357 e 21.24 9.46 21 21 446 199 21 21 446 199 VW 12F-0sw 0.065 s 3.87 0.99 392 362 1399 360 0 0 0 0 1 G Low-E Vinyl Frame Wi 0.350 s 20.82 2267 30 0 625 680 0 0 0 0 W 15B13-0wc-6 0.093 s 3,81 0.27 161 161 612 44 161 161 612 44 12F-0sw 0.065 w 3.87 0.99 390 363 1404 361 0 0 0 0 Low-E Vinyl Frame Wi 0.350 w 20.82 39.75 6 0 125 238 0 0 0 0 R 2-8 U 357 0.357 w 21.24 9.46 21 21 446 199 0 0 0 0 W 15813-Owc-6 0.093 w 3.81 0.27 351 351 1339 96 351 351 1339 96 C 16B-38ad 0.026 - 1.55 1.30 1528 1528 2363 1986 0 0 0 0 F 20P-30c 0.035 - 2.08 0.35 832 832 1733 291 0 0 0 0 F 21A-28t 0.022 - 1.31 0.00 696 696 910 0 696 696 910 0 6 c) AED excursion 0 -21 Envelope loss/gain 19651 10470 5143 437 12 a) Infiltration 3678 618 566 95 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants t 230 2 460 0 0 Appliances/other 2600 0 Subtotal (lines 6 to 13) 23330 14149 5708 532 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 23330 14149 5708 532 15 Duct loads 20% 21% 4672 3032 4% 8% 231 43 Total room Toad 28002 17180 5940 575 Air required (cfm) 790 870 168 29 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A -� wrlightsoft" Right -Suite® Universal 2017 17.0.16 RSU14545 .. MORTIMER ADDITION - dave1MORTIMER ADDITION.rup Calc = MJ8 Front Door faces: N 2017-Mar-02 14:14:29 Page 1 -F wrightsoft Right-J® Worksheet Entire House Idaho HVAC Design LLC ID Phone: 989-0098 Email: Geoff@IdahoHVAC.com Web www.IdahoHVACDesign.com Job: Date: 02/27/2017 By: 1 Room name GREAT RM/KITCHEN BH 2 Exposed wall 74.7 ft 0 ft 3 Room height 10, 0 ft heat/cool 10.0 ft heat/cool 4 Room ctmensions 1 0 x 777.4 ft 1.0 x 71.5 ft 5 Room area 777.4 ft2 71.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load number (Btuhlft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross NIP/S Heat Cool 6 Id 12F-0sw 0.065 n 3.87 0.99 178 130 502 129 0 0 0 0 -G 1004 0.350 n 20.82 9.55 21 0 437 201 0 0 0 0 -G Low-E Vinyl Frame Wi 0.350 n 20.82 13.64 0 0 0 0 0 0 0 0 - G Law-E Vinyl Frame Wi 0.350 n 20.82 13.64 0 0 0 0 0 0 0 0 11 -G Low-E Vinyl Frame Wi 0.350 n 20.82 13.64 28 0 573 375 0 0 0 0 W 15813-0wc-6 0.093 n 3.81 0.27 0 0 0 0 0 0 0 0 N/ 12F-osw 0.065 e 3.87 0.99 390 272 1050 270 0 0 0 0 - G 10D-f 0.350 e 20.82 27.82 35 0 729 974 0 0 0 0 -G Law-E Vinyl Frame Wi 0.350 e 20.82 39.75 20 0 416 795 0 0 0 0 -G Low-E Vinyl Frame Wi 0.350 e 20.82 39.75 28 0 573 1093 0 0 0 0 --43 Low-E Vinyl Frame Wi 0.350 e 20.82 39.75 36 0 750 1431 0 0 0 0 W 15B13-0wc-6 0.093 a 3.71 0.23 0 0 0 0 0 0 0 0 I-D R 2-8 U 357 0.357 e 21.24 9.46 0 0 0 0 0 0 0 0 V 12F-Osw 0.065 s 3.87 0.99 178 178 690 177 0 0 0 0 L-C3 Low-E Vinyl Frame Wi 0.350 s 20.82 2267 0 0 0 0 0 0 0 0 W 15B13-0wc-6 0.093 s 3.81 0.27 0 0 0 0 0 0 0 0 W 12F-Osw 0.065 w 3.87 0.99 0 0 0 0 0 0 0 0 LI-_Cp; Low-E Vinyl Frame Wi 0.350 w 20.82 39.75 0 0 0 0 0 0 0 0 R 2-8 U 357 0.357 w 21.24 9.46 0 0 0 0 0 0 0 0 W 15B13-Owc-6 0.093 w 3.81 0.27 0 0 0 0 0 0 0 0 C 168-38ad 0.026 - 1.55 1.30 777 777 1203 1011 72 72 111 93 F 20P-30c 0.035 - 208 0.35 82 82 171 29 72 72 149 25 F 21A-28t 0.022 - 1.31 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -87 -4 Envelope Toss/gain 7093 6397 260 114 12 a) Infiltration 1487 250 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2100 0 Subtotal (lines 6 to 13) 8579 8747 260 114 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 85 37 -260 -114 14 Subtotal 8665 8784 0 0 15 Duct loads • 25% 22% 2183 1928 25% 22% 0 0 Total room load 10848 10712 0 0 Air required (cfm) 306 542 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .. - wrig htsoft" Right -Suite® Universal 2017 17.0.16 RSU14545 .. MORTIMER ADDITION - dave1MORTIMER ADDITION.rup Calc = MJ8 Front Door faces: N 2017-Mar-02 14:14:29 Page 2 - wrightsoft Right-J® Worksheet Entire House Idaho HVAC Design LLC ID Phone: 989-0098 Email: Geoff@IdahoHVAC.com Web www.IdahoHVACDesign.com Job: Date: 02/27/2017 By: 1 Room name MASTER BH MASTER BD 2 Exposed wall 12.3 ft 12.8 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 161.1 ft 12.8 x 13.4 ft 5 Room area 161.1 ft' 172.2 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft2--'F) (Btutyft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 lid 12F-Osw 0.065 n 3.87 0.99 0 0 0 0 128 98 380 98 -G 100-f 0.350 n 20.82 9.55 0 0 0 0 0 0 0 0 - G Low-E Vinyl Frame Wi 0.350 n 20.82 13.64 0 0 0 0 0 0 0 0 -G Law-E Vinyl Frame Wi 0.350 n 20.82 13.64 0 0 0 0 30 0 625 409 11 -G Law-E Vinyl Frame Wi 0.350 n 20.82 13.64 0 0 0 0 0 0 0 0 W 15813-Owc-6 0.093 n 3.81 0.27 0 0 0 0 0 0 0 0 V,J 12F-Osw 0.065 a 3.87 0.99 0 0 0 0 0 0 0 0 - G 10D-f 0.350 a 20.82 27.82 0 0 0 0 0 0 0 0 -G Lew-E Vinyl Frame Wi 0.350 e 20.82 39.75 0 0 0 0 0 0 0 0 -G Law-E Vinyl Frame Wi 0.350 e 20.82 39.75 0 0 0 0 0 0 0 0 -G Low-E Vinyl Frame Wi 0.350 e 20.82 39.75 0 0 0 0 0 0 0 0 V)1 15B13-Owc-6 0.093 a 3.71 0.23 0 0 0 0 0 0 0 0 O R 2-8 U 357 0.357 a 21.24 9.46 0 0 0 0 0 0 0 0 V1 12F-Osw 0.065 s 3.87 0.99 0 0 0 0 0 0 0 0 VG Low-E Vinyl Frame Wi 0.350 s 20.82 22.67 0 0 0 0 0 0 0 0 W 151313-0wc-6 0.093 s 3.81 0.27 0 0 0 0 0 0 0 0 12F-0sw 0.065 w 3.87 0.99 123 117 451 116 0 0 0 0 Law-E Vinyl Frame Wi 0.350 w 20.82 39.75 6 0 125 238 0 0 0 0 R 2-8 U 357 0.357 w 21.24 9.46 0 0 0 0 0 0 0 0 W 15B13-Owc-6 0.093 w 3.81 0.27 0 0 0 0 0 0 0 0 C 168-38ad 0.026 - 1.55 1.30 161 161 249 209 172 172 266 224 F 20P-30c 0.035 - 2.08 0.35 161 161 336 56 172 172 359 60 F 21A-28t 0.022 - 1.31 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 90 -49 Envelope loss/gain 1160 710 1630 742 12 a) Infiltration 244 41 255 43 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 1404 751 1885 1245 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 106 46 0 0 14 Subtotal 1510 797 1885 1245 15 Duct loads 25% 22% 380 175 25% 22% 475 273 Total room Toad 1890 972 2361 1519 Air required (cfm) 53 49 67 77 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A. � wrightsaftt- Right -Suite® Universal 2017 17.0.16 RSU14545 .. MORTIMER ADDITION - dave1MORTIMER ADDITION.rup Calc = MJ8 Front Door faces: N 2017-Mar-02 14:14:29 Page 3 -- wrightsoft Right-J® Worksheet Entire House Idaho HVAC Design LLC ID Phone: 989-0098 Email: Geoff@IdahoHVAC.com Web: www.IdahoHVACDesign.com Job: Date: 02/27/2017 By: 1 Room name MASTER WIC LAUNDRY/MUD RM 2 Exposed wall 21.9 ft 34.7 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 8.5 x 13.4 ft 1.0 x 231.2 ft 5 Room area 114.0 ft' 231.2 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft2 °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vr! 12F-0sw 0.065 n 3.87 0.99 85 82 317 82 0 0 0 0 -G 1004 0.350 n 20.82 9.55 0 0 0 0 0 0 0 0 -G Low-E Vinyl Frame Wi 0.350 n 20.82 13.64 3 0 62 41 0 0 0 0 - G Low-E Vinyl Frame Wi 0.350 n 20.82 13.64 0 0 0 0 0 0 0 0 11 --G Low-E Vinyl Frame Wi 0.350 n 20.82 13.64 0 0 0 0 0 0 0 0 W 15B13-0wc-6 0.093 n 3.81 0.27 0 0 0 0 0 0 0 0 (d 12F-0sw 0.065 a 3.87 0.99 0 0 0 0 0 0 0 0 - 6 100-f 0.350 a 20.82 27.82 0 0 0 0 0 0 0 0 -G Low-E Virtl Frame Wi 0.350 e 20.82 39.75 0 0 0 0 0 0 0 0 -G Low-E Vinyl Frame Wi 0.350 e 20.82 39.75 0 0 0 0 0 0 0 0 ---3 Low-E Vinyl Frame Wi 0.350 e 20.82 39.75 0 0 0 0 0 0 0 0 V)1 15813-0wc-6 0.093 e 3.71 0.23 0 0 0 0 0 0 0 0 I---O R 2-8 U 357 0.357 a 21.24 9.46 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 s 3.87 0.99 0 0 0 0 213 183 709 182 I-L' Low-E Vinyl Frame Wi 0.350 s 20.82 2267 0 0 0 0 30 0 625 680 W 15813-Owc-6 0.093 s 3.81 0.27 0 0 0 0 0 0 0 0 11, 12F-0sw 0.065 w 3.87 0.99 134 134 519 133 133 112 434 112 Low-E Vinyl Frame Wi 0.350 w 20.82 39.75 0 0 0 0 0 0 0 0 R 2-8 U 357 0.357 w 21.24 9.46 0 0 0 0 21 21 446 199 W 15B13-0wc-6 0.093 w 3.81 0.27 0 0 0 0 0 0 0 0 C 16B-38ad 0.026 - 1.55 1.30 114 114 176 148 231 231 358 301 F 20P-30c 0.035 - 208 0.35 114 114 237 40 231 231 482 81 F 21A-28t 0.022 - 1.31 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -20 91 Envelope loss/gain 1312 425 3054 1646 12 a) Infiltration 436 73 690 116 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants © 230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13) 1749 498 3744 2262 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 69 30 14 Subtotal 1749 498 3813 2292 15 Duct loads 25% 22% 441 109 25% 22% 961 503 Total room Toad 2189 607 4773 2795 Air required (cfm) 62 31 135 142 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. . A - + wrightsaft" Right -Suite® Universal 2017 17.0.16 RSU14545 .. MORTIMER ADDITION - dave\MORTIMER ADDITION.rup Calc = MJ8 Front Door faces: N 2017-Mar-02 14:14:29 Page 4 Ret Riser 16" Job #: Performed for: MORTIMER ADDITION BASEMENT BASEMENT Sup Riser JJ 20x16 ., Ret Riser 16' 10 168 cfm 4x10 84 cfm 0 4 x 10 84 cfm Idaho HVAC Design LLC ID Phone: 989-0098 www.IdahoHVACDesign.com Geoff@IdahoHVAC.com Scale: 1 : 118 Page 1 Right -Suite® Universal 2017 17.0.16 RSU14545 2017-Mar-02 14:14:36 ...ION - dave\MORTIMER ADDITIO... 1 MASTER WK. MASTER B:: 4 x 10 - 62 cfm 6 " 6 x 14 142 cfm Job #: Performed for: MORTIMER ADDITION 12" 182 cfm LAUNDRY/MUD RM 8" LEVEL 1 4 x 10 n 77 cfm 6 "1 20 " 6 x 14 181 cfm 6 411.ii 4116 181 cfm ?RE.Ai RMIK!T CHEN 20x8 684 cfm Sup Riser 20 x 16 12.,& 20 x 8 SUPPLY DUCT WORK LOCATED IN BASEMENT AND CRAWLSPACE Idaho HVAC Design LLC 'in., >6 6 x 14 181 cfm ID Phone: 989-0098 www.IdahoHVACDesign.com Geoff@IdahoHVAC.com Scale: 1 : 118 Page 2 Right -Suite® Universal 2017 17.0.16 RSU14545 2017-Mar-02 14:14:36 ...ION - davelMORTIMER ADDITIO... NOTES Disclaimer: By using the Wrightsoft Design and Information the HVAC contractor and General Contractor agree to complete liability and hold Idaho HVAC Design harmless for any and all failures with the system and/or potential legal actions that may arise due to a non compliant heating and cooling system instated by the HVAC contractor and designed by Idaho HVAC Design and or its Employees, Partners and or Subcontracted labors. Idaho HVAC Design and/or its Employees, Partners and or Subcontracted labors are not responsible for the following; air flows, heating and cooling bills, actual heating or cooling Toads. The HVAC Contractor and/or General Contractor assumes full responsibility for the Wrightsoft Calculations and any and al deficiencies in the installed system. This drawing is the exclusive property of Idaho HVAC Design and must not be reproduced without their written permission. Crawlspaces: Provide Knockouts in ribbon footings for trunk lines. Provide 4" minimum clearance between the bottom of the duct and conductive surfaces. Add 4" to the diameter of the duct to fund the approx true diameter. Registers: Main Return Grill size options 1050 Series Shoemaker or equivalent. Floor Register Selections Must be equivalent to Shoemaker 350 series. Ceiling Register Selections Must be equivalent to Shoemaker 850 series. Four way Ceiing Register Selection Must be equivalent to Shoemaker 150 Series. Dampeners: Balance dampeners to be installed one foot from the beginning of each branch run. Holes caused by installation of the dampeners are to be sealed after correct supply flows have been established. Alterations: Please contact Idaho HVAC Design before making any alterations from the approved plan. Air Handler. Fan sThe following items must be addressed at HVAC final; AC Coil to cleaned, blower to be cleaned, fan speed to be set and bbwer access panel taped shut. If Fan speed is the same for Heating and Cooing, the fan must be jumpered. Filter: Filter should not exceed static pressure drop of approved filter by furnace manufacturer plus an additional .10 drop. Job #: Performed for: MORTIMER ADDITION Idaho HVAC Design LLC ID Phone: 989-0098 www.IdahoHVACDesign.com Geoff@IdahoHVAC.com Scale: 1:118 Page 3 Right -Suite® Universal 2017 17.0.16 RSU14545 2017-Mar-02 14:14:36 ...ION - davelMORTIMER ADDITIO... +- wrightsoft Duct System Summary Entire House Idaho HVAC Design LLC ID Phone 989-0098 Email Geoff@IdahoHVAC.com Web wvw IdahoHVACDesign.com Job: Date: 02/27/2017 By: Project Information` For: 11 11 11111 1111 1111 MORTIMER ADDITION, 426 N EDGEWOOD, EAGLE External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) 1, 1.1 1 . II. l1 !I 1 1 11111111111111, II III IL! H MI', Heati ng 0.70 in H2O 0.44 in H2O 0.26 in H2O 0.166/0.094 in H2O 0.072 in/100ft 790 cfm 359 ft Cooling 0.70 in H2O 0.48 in H2O 0.22 in H2O 0.141/0.079 in H2O 0.061 in/100ft 870 cfm Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk BASEMENT -A h 2970 84 15 0.082 6.0 0x 0 VIFx 22.4 180.0 st1 BASEMENT-B h 2970 84 15 0.074 6.0 0x 0 VIFx 34.4 190.0 st4 GREAT RM/KITCHEN c 3572 102 181 0.061 8.0 Ox 0 VIFx 45.0 185.0 st4 GREAT RMlKITCHEN-A c 3571 102 181 0.062 8.0 Ox 0 VIFx 33.2 195.0 st4 GREAT RMIKITCHEN-8 c 3571 102 181 0.065 8.0 Ox 0 VIFx 15.3 200.0 st4 LAUNDRY/MUD RM c 2795 135 142 0.070 8.0 0x 0 VIFx 31.3 170.0 st2 MASTER BD c 1519 67 77 0.066 6.0 0x 0 VIFx 28.8 185.0 st2 MASTER BH h 972 53 49 0.073 6.0 0x 0 VIFx 26.6 165.0 st2 MASTER WIC h 2189 62 31 0.080 6.0 0x 0 VIFx 34.0 175.0 st2 SupplyTrunk Detail Table` Trunk Htg Name Type (cfm) Clg Design Veloc Diam H x W Duct (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 390 557 0.061 501 12.6 8 x 20 ShtMetl st1 st1 Peak AVF 474 572 0.061 514 12.9 8 x 20 ShtMetl srsl srs1 Peak AVF 790 870 0.061 392 12.9 16 x 20 ShtMetl st2 Peak AVF 316 298 0.066 403 12.0 0 x 0 VinlFlx srsl . wrightsoft.' Right -Suite® Universal 2017 17.016 RSU14545 ACC11 .. MORTIMER ADDITION - dave\MORTIMER ADDITION rup Calc = MJ8 Front Door faces N 2017-Mar-02 14 14:30 Page 1 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 rb4 rb3 0x 0 168 29 62.6 0.150 480 8.0 Ox 0 0x 0 441 684 128.6 0.062 490 16.0 0x 0 Ox 0 182 157 129.4 0.072 333 10.0 0x 0 VIFx rrsl VIFx rrs2 VIFx rrs2 Return TrunkDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rrsl PeakAVF 790 870 0.061 623 16.0 0 x 0 ShtMetl rrs2 Peak AVF 622 841 0.061 602 16.0 0 x 0 ShtMetl rt1 rt1 Peak AVF 622 841 0.061 602 16.0 0 x 0 VinIFIx rrsl szi wrightsoft Right -Suite® Universal 2017 17 016 RSU14545 CCK MORTIMER ADDITION - dave1MORTIMER ADDITION rup Calc = MJ8 Front Door faces. N 2017-Mar-02 14-14-30 Page 2