Flood Control - Elevation Certificate - 1270 E Lone Shore Drive - Lonesome Dove Sub - 8/19/2010
U.S. DEPARTMENT OF HOMELAND SECURITY
Federal Emergency Management Agency
National Flood Insurance Program
ELEVATION CERTIFICATE
OMS No. 1660-0008
Expires March 31, 2012
Important: Read the instructions on pages 1-9.
SECTION A - PROPERTY INFORMATION
A1. Building Owner's Name Taunton Properties, LLC
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
1270 E. Lone Shore Drive
City Eagle State ID ZIP Code 83616
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
Lot 5, Block 8 Lonesome Dove Subdivision
A4. Building Use (e.g., Residential, Non-Residential, Addition, Accessory, etc.) Residential
A5. Latitude/Longitude: Lat. N43041'13" Long. W116020'16" Horizontal Datum: 0 NAD 1927 [8J NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
A7. Building Diagram Number 1 B
A8. For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage:
a) Square footage of crawlspace or enclosure(s) N/A sq ft a) Square footage of attached garage 438.5 sq ft
b) No. of permanent flood openings in the crawlspace or b) No. of permanent flood openings in the attached garage
enclosure(s) within 1.0 foot above adjacent grade N/A within 1.0 foot above adjacent grade N/A
c) Total net area of flood openings in A8.b N/A sq in c) Total net area of flood openings in A9.b N/A sq in
d) Engineered flood openings? 0 Yes [8J No d) Engineered flood openings? 0 Yes [8J No
SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number
Eagle 160003
B2. County Name
Ada
B3. State
Idaho
84. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone
16001C0162 H Date Effective/Revised Date Zone(s) AO, use base flood depth)
September 22, February 19, 2003 AE 2567.8
1999
B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9.
o FIS Profile I2J FIRM 0 Community Determined 0 Other (Describe) _
B11. Indicate elevation datum used for BFE in Item B9: 0 NGVD 1929 I2J NAVD 1988 0 Other (Describe) _
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? 0 Yes
Designation Date _ 0 CBRS DOPA
I2J No
SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
C1. Building elevations are based on: 0 Construction Drawings* 0 Building Under Construction* I2J Finished Construction
*A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations -Zones A1-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, ARIA, ARlAE, ARlA1-A30, ARlAH, ARlAO. Complete Items C2.a-h
below according to the building diagram specified in Item A7. Use the same datum as the BFE.
Benchmark Utilized Project Benchmark Vertical Datum NAVD 88
Conversion/Comments
a)
b)
c)
d)
e)
Top of the next higher floor
Bottom of the lowest horizontal structural member (V Zones only)
Attached garage (top of slab)
Lowest elevation of machinery or equipment servicing the building
(Describe type of equipment and location in Comments)
Lowest adjacent (finished) grade next to building (LAG)
Highest adjacent (finished) grade next to building (HAG)
Lowest adjacent grade at lowest elevation of deck or stairs, including
structural su pport
2582.1
N/A._
2571-1
2571.Q
Check the measurement used.
I2J feet 0 meters (Puerto Rico only)
[gJ feet 0 meters (Puerto Rico only)
o feet 0 meters (Puerto Rico only)
I2J feet 0 meters (Puerto Rico only)
[8J feet 0 meters (Puerto Rico only)
Top of bottom floor (including basement, crawlspace, or enclosure floor) 2571.1
f)
g)
h)
2569.~
2570.~
N/A._
I2J feet 0 meters (Puerto Rico only)
I2J feet 0 meters (Puerto Rico only)
o feet 0 meters (Puerto Rico only)
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation
information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I
understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001.12J
Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a
licensed land surveyor? I:8l Yes D No
Address 391 W, State St.
City Eagle
State ID
ZIP Code 83616
Certifier's Name Kevin N. Sorensen
License Number 11120
Title Professional Surveyor
Company Name KM Engineering LLP
Signature
Date 08-19-2010
Telephone 208-639-6939
FEMA Form 81-31, Mar 09
See reverse side for continuation.
Replaces all previous editions
IMPORTANT: In these spaces, copy the corresponding information from Section A.
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
1270 E. Lone Shore Dr.
City Eagle State ID ZIP Code 83616
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED)
Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agenUcompany, and (3) building owner.
Comments The equipment sevicing the building is an airconditioning unit located at the Southwest comer of the building.
o Check here if attachments
SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE)
Date 08-19-2010
Signature
For Zones AO and A (without BFE), complete Items E1-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,
and C. For Items E1-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters.
E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent
grade (HAG) and the lowest adjacent grade (LAG).
a) Top of bottom floor (including basement, crawlspace, or enclosure) is _'_ 0 feet 0 meters 0 above or 0 below the HAG.
b) Top of bottom floor (including basement, crawlspace, or enclosure) is _'_ 0 feet 0 meters 0 above or 0 below the LAG.
E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 8-9 of Instructions), the next higher floor
(elevation C2.b in the diagrams) of the building is _'_ 0 feet 0 meters 0 above or 0 below the HAG.
E3. Attached garage (top of slab) is _'_ 0 feet 0 meters 0 above or 0 below the HAG.
E4. Top of platform of machinery and/or equipment servicing the building is _'_ 0 feet 0 meters 0 above or 0 below the HAG.
E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management
ordinance? 0 Yes 0 No 0 Unknown. The local official must certify this information in Section G.
SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION
The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community-issued BFE)
or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge.
Property Owner's or Owner's Authorized Representative's Name
Address
City
State
ZIP Code
Signature
Date
Telephone
Comments
o Check here if attachments
SECTION G - COMMUNITY INFORMATION (OPTIONAL)
The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E),
and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8 and G9.
G1. 0 The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who
is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.)
G2. 0 A community official completed Section E for a building located in Zone A (without a FEMA-issued or community-issued BFE) or Zone AO.
G3. 0 The following information (Items G4-G9) is provided for community floodplain management purposes.
G4. Permit Number
G5. Date Permit Issued
G6. Date Certificate Of Compliance/Occupancy Issued
G7. This permit has been issued for: 0 New Construction 0 Substantial Improvement
G8. Elevation of as-built lowest floor (including basement) of the building: _'_ 0 feet 0 meters (PR) Datum _
G9. BFE or (in Zone AO) depth of flooding at the building site: _ _ 0 feet 0 meters (PR) Datum _
G10. Community's design flood elevation _ _ 0 feet 0 meters (PR) Datum _
Local Official's Name
Title
Community Name
Telephone
Signature
Date
Comments
o Check here if attachments
FEMA Form 81-31, Mar 09
Replaces all previous editions
Building Photographs
See Instructions for Item A6.
For Insurance Company Use:
Building Street Address (including Apt, Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number
1270 E. Lone Shore Dr.
City Eagle State ID ZIP Code 83616 Company NAlC Number
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to
the instructions for Item A6. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right
Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page,
following.
July 29,2010 Front View (East Side).
July 29, 2010 Rear View (West Side).