Loading...
Pool - NA - 2272 N Synergy Pl - 03/25/2019No._ City of Eagle Building Permit Application - Residential THE UNERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS: Contractor Co. Name:IPremier Pools and Spas State License# ]RCE-34974 Contact Name: Todd Rowey Company Address:1439 E. Shore Dr. # 220 City, State, Zip Eagle, Idaho, 83616 Structure Type: (' New (Choose one from each row) C Home C Garage C Addition Expiration Date:13/25/2019 C Shed (: Pool FOOTINGS EXTERIOR INSULATION I— Concrete r Wood r ResCheck r Masonry r Masonry r Prescriptive FOUNDATION r Concrete BASEMENT r Concrete r Vaneer r Yes r Masonry r Metal r No INTERIOR WALLS ✓ Drywall Firewall ✓ Other Building Department Information Shaded area to be completed by Building Department Phone:1208-286-4988 ............. ................ Fax: (' Remodel C- Other C Patio C' Other ROOF r Shingle r Tile r Other Remark, Date 1/23/2019 Home OwnerlBrett & Kathy Humphries Owner Address:I2272 N. Synergy PL. City, State, Zip !Eagle, Idaho, 83616 Owner Phone CEILING FLOORS HEAT r Drywall E Wood r Gas r Grid r Concrete r Electric r Other r Other r Other City's Date Stamp " I THIS PERMIT is issued subject to the regulations contained in the 2009 Building Code and Zoning Regulations of the City of Eagle and it is hereby agreed that the work be done as shown in the plans and specifications will be completed in accordance with the regulations pertaining and applicable thereto: In -ground concrete swimming pool w/400k BTU gas heater Value $ 47,500 Sq. Ft. - Living Area Permit Fee $ Sq. Ft. - Basement APPLICANT IS RESPONSIBLE FOR LOCATION OF ALL PROPERTY LINES AND SET BACKS Plan Review Fee.. $ Sq. Ft. - Garage In 100 Yr Floodplain? � (' Yes rNo LotI 16 Block: I Lot Size:[ .662 acres IECC Fee $ Sq. Ft. - Porch Mech Review Fee .$ _ Occupancy Group/Division Subdivision: (Lilac Springs #2 P&Z Review Fee .. $ Zone Type: V-B Dev Impact Fee .. $ BP TOTAL DUE ...$ ACHD Impact Fee $ City of Eagle Water $ Deposit Received . Total with Water. $ Permit Address:12272 N. Synergy PI. Eagle, ID. 83616 IH0A/ACC Required? (' No C Yes Receipt # Building Official Applicant Signature W Nordic Dr 2272 N. SYNERGY PL. u Floating Fcnlhcr Rd 14' Piaffe St W Ci Or 7.6 W Foul ndop, �r W CmMndalle p, W Floating Fralher Rd W'Signature 1)! OI'os aP .4 p9 G'- 7 Nc[1h Star Charter 11 School k�,p�f�nc GPI+ko nl C100 71/ A I. t irmaliFiv. a w . 11 II Pr I C101 SITE MAP SCALE: NO SCALE CONCEPT DRAWING SCALE: NO SCALE � passion for spiashiri' Al - SITE PLAN A2- POOL PLAN A3 POOL LAYOUT A4- - A5- - A6- - A7- - A8- POOL COVER-1 A9- POOL COVER 2 D1- - D2- - D3- - D4- - P1-- P2- - P3- - El- ELECTRICAL S 1 — STUCTURAL TABLE OF CONTENTS U J J v) Q co (1) cn 0 0 Cr) • E d) ^L 0 J U)o (7;$ WOZCO W J o IzmOO u)(Cs Uw DI—Q0 IcyOJQ N J W N N Designer: Plans By: Date: SCOTT LAING TODD ROWEY 1/23/2019 Revision Date: Revision Date: THIS PLAN IS PROPERTY OF PREMIER POOLS AND SPAS, LLC. ANY FORM OF DUPLICATION OR USE OF ALL OR ANY PLANS, DRAWINGS, OR DESIGNS IS PROHIBITED. COPYRIGHT 2018 COVER Cl ELECTRIC POOL COVER \ ^OPERTY LINE POOL EQUIPMENT \ \ \ A100 J SP DECKING EXISTING PATIO L 1 PROPOSED POOL L EXISTING HOME SITE PLAN SCALE: 1/16"= 1' EXISTING PATIO N / / / / / PROPERTY LINE / / Premier Pools and Spas LLC 439 E. Shore Dr. Suite 200 Eagle, ID. 83616 (208)-286-4988 www.ppas.com J - o () W_�0zCO O 00 W J o =zma_o IcyOJQ N J W N N Designer: SCOTT LAING Plans By: TODD ROWEY Date: 1/23/2019 Revision Date: Revision Date: THIS PLAN IS PROPERTY OF PREMIER POOLS AND SPAS, LLC. ANY FORM OF DUPLICATION OR USE OF ALL OR ANY PLANS, DRAWINGS, OR DESIGNS IS PROHIBITED. COPYRIGHT 2018 SITE PLAN Al NOTE: REFER TO STRUCTURAL DETAILS PAGE S1 DIVING BOARD-\ H3A03IOOd 0IH10313 POOL PLAN J BENCH (BB-21") DRAI [iENCH BB21) LED LIGHT 0 w w 0 LECTRIC POOL COVER TO COMPLY WITH ASTM F1346-91 LED LIGHT SCALE = 3/16" = 1' POOL SLID w w 0 SKIMMERS: REFER TO SECTION 9, PAGE 100 I_ED LIGHT 3' 6" DEEP STEP 7<______ (BB-33") PLAY SHELF (BB -21 ") STEP (BB-9") /LED LIGHT POOL DETAILS MAX. WIDTH: MAX. LENGTH: DEPTH: PERIMETER: SURFACE AREA: EST. INT. AREA: EST. GALLONS: TURNOVER RATE: GPM: —CHECK WITH CONTRACTOR FOR UMBRELLA SLEEVE LOCATIONS 20' 45' 3.5' to 5' to 9' 130' 900 Sq. Ft. 1,626 Sq. Ft. 35,346 6 Hrs./360 Min. 99 Premier Pools and Spas LLC 439 E. Shore Dr. Suite 200 Eagle, ID. 83616 (208)-286-4988 www.ppas.com fn CO (� CO WOOZCO O 00 W J o =zco 0_ 2Cna)UW IH IS 0 cyOJQ N J W CN N Designer: SCOTT LAING Plans By: TODD ROWEY Date: 1/23/2019 Revision Date: Revision Date: THIS PLAN IS PROPERTY OF PREMIER POOLS AND SPAS, LLC. ANY FORM OF DUPLICATION OR USE OF ALL OR ANY PLANS, DRAWINGS, OR DESIGNS IS PROHIBITED. COPYRIGHT 2018 POOL PLAN A2 COVER BOX -SIDE NER.�NPN S� PN, d ° I2 N\G ° 2-1/2" LOWER THA o 1 (STANDARD BOND BEAM . I°I I I I IHHHH I QI ° 12 ° I I I�oE ° A III I I I I I IIIII I I I I I IIIII STEP UP FORMS 1" FRO "STANDARD POOL BOND BEAM" FOR THE SIDES AND BACK OF THE COVER BOX. I I I - 4 4 4 • • POOL COVER DRAIN SCALE = 3/4" = l' 1-1/2" HIGHER THAN STANDARD BOND BEAM POOL COVER BOX -DETAIL SCALE = NO SCALE d • 4 ° ACK OF COVER DAM WALL 2-1/2" BELOW "STANDARD POOL BOND BEAM" STANDARD POOL BOND BEAM FRONT OF COVER DAM WALL 3-1/2" BELOW "STANDARD POOL BOND BEAM" 3" COVER BOX DRAIN (X3) OPRO BONO 6EPM ER INPN S� PN III • Orr N�C'N 2-1/2" LOWEIRITHIA II I I I I STANDARD BOND BEAM I I • ° 1,0:. d m 1„ SLOPE I\ • d a° SPA COVER BOX -DETAIL 414 • 1-1/2" HIGHER THAN STANDARD BOND BEAM .4„ i11111 3-1/2' LOWER THAN STANDARD BOND BEAM SCALE = NO SCALE Premier Pools and Spas LLC 439 E. Shore Dr. Suite 200 Eagle, ID. 83616 (208)-286-4988 www.ppas.com J U)>-4n9(7) WOOZ0 co CO W J o IzmOO u)(c)Uw =CVOQ N J W N Designer: SCOTT LAING Plans By: TODD ROWEY Date: 1/23/2019 Revision Date: M Revision Date: THIS PLAN IS PROPERTY OF PREMIER POOLS AND SPAS, LLC. ANY FORM OF DUPLICATION OR USE OF ALL OR ANY PLANS, DRAWINGS, OR DESIGNS IS PROHIBITED. COPYRIGHT 2018 COVER BOX FORMING A8 COVER TRACK-\ EASURE FROM CENTER OF COVER TRACK r-COVER TRACK TOP OF BOND BEAIVH� • } COVER LI MOTORIli Z.\ ;1-._ -CLEARANCE �i.:\I FROM TILE •>OovOoU0oU0oU0oU0oUGRAVEL'�UoUoUoUoUoUoUoUoUoUoUoUoUC' . EXISTING BOND BEAM 2'-8" - - 1'4 COVER BOX -END EXISTING BOND BEAM COVER MOTOR 2'-8" DRAIN 4" N-3" DRAIN 3" CONCRETE SCALE = 1/2" = 1' EXISTING BOND BEAM- POOL OVER MECHANICS CENTER OF BOX DRAIN -EXISTING BOND BEAM COVER TRAC-\ K o�_l o�.—._ �� �v ..........��.�_� • V1 , - - GRAVEL r, I��f- > o o moo• o• ov o��•o•�• . •�•o•o•o•o•o•�•���• �������Xiie"!•iti>♦��Il♦mil♦etI-*il11",l "dliA&atebAdi itdib&atilisot e&so 1'- COVER BOX -TOP COVER DRAINS WITH WIRE MESH AND LANDSCAPE FABRIC SCALE = 1/2" = 1' 3" DRAINS f -1'- 10" OVER MECHANICS Premier Pools and Spas LLC 439 E. Shore Dr. Suite 200 Eagle, ID. 83616 (208)-286-4988 www.ppas.com J U)o Cc$ WOOZCO ry C O 00 W J o • IzmOO 2u)c°Uw DI—Q0 IcyOJQ N J W CN CN Designer: SCOTT LAING Plans By: TODD ROWEY Date: 1/23/2019 Revision Date: Revision Date: THIS PLAN IS PROPERTY OF PREMIER POOLS AND SPAS, LLC. ANY FORM OF DUPLICATION OR USE OF ALL OR ANY PLANS, DRAWINGS, OR DESIGNS IS PROHIBITED. COPYRIGHT 2018 COVER BOX FLOOR A9 ELECTRICAL ITEMS NEEDED: BONDING ITEMS: • Main pool bonding to structural steel & equipment • Deck bonding • Water bonding (AQUASTAR skimmer w/bonding plate - model # SKR15103) • Pool cover bonding CONDUITS TO THE POOL: • 4 Low Voltage nicheless lights. J-Box by electrical panels • 1 Electrical to pool cover motor EQUIPMENT & OTHER ITEMS: • Electrical home run • Jandy Aqualink RS-P6 automation panel with built in sub -panel • Jandy Onetouch panel (mounted by equipment in exterior box) • iAqualink antenna for smartphone • Low voltage transformer(s) for lights • (1) 1.5 hp pump for pool circulation (high voltage power & low voltage for automation) • (1) 400,000 BTU Gas heater • Key switch for cover CONTACT CONTRACTOR ABOUT COVER SWITCH LOCATION ELECTRICAL CONDUIT • a, 1 STANDARD LIGHT 1'-9" (21 ") FROM TOP OF BOND BEAM EAVE 6" OF PIPE EXPOSED PAST SHOTCRETE a3A03 100d 31.10313 LEAVE 6" OF — PIPE EXPOSED • ELECTRICAL CONDUIT • 4 PROPOSED POOL 10" BELOW TOP OF BOND BEAM WATERLINE 1/- 2 PLAYSHELF LIGHT • 4 < e Premier Pools and Spas LLC 439 E. Shore Dr. Suite 200 Eagle, ID. 83616 (208)-286-4988 www.ppas.com J C� WOo Z OCO O °o W J o• IzmOO 0_ 2Cn(°UW �Zf—QC� I cyO—< N J W N N Designer: Plans By: Date: SCOTT LAING TODD ROWEY 1 /23/2019 Revision Date: Revision Date: THIS PLAN IS PROPERTY OF PREMIER POOLS AND SPAS, LLC. ANY FORM OF DUPLICATION OR USE OF ALL OR ANY PLANS, DRAWINGS, OR DESIGNS IS PROHIBITED. COPYRIGHT 2018 ELECTRICAL El STEEL CONFIGURATION: • #3 REBAR SPACED 12" ON CENTER VERTICALLY AND HORIZONTALLY FOR ALL WALLS AND FLOORS. • WALLS GREATER THAN 5', AND UP TO 8'-6" - ADD #3 REBAR TO BE 6" ON CENTER VERTICALLY. • POOLS WITH DEEP END TRANSITION - ADD #3 REBAR TO BE 6" ON CENTER VERTICALLY, TO EXTEND 5' BEYOND EACH SIDE OF THE TRANSITION POINT • PREMIER POOLS AND SPAS® NATIONAL STANDARD FOR ALL BOND BEAM STEEL UTILIZES FOUR (4) PIECES OF #4. SEE BOND BEAM DETAIL STANDARD NOTES 24" POOL? IN p AP 4 4` d d c .4 3" CLR: TYPICAL I / PLAN AT SKIMMER / !' MIN. TYPICAL DRAIN 4NDISTURBED SOIL 1500 PSF MIN. BEARING VALUE "C" SHOTCRETE COVE TO BE CHANGED UNIFORMLY SEE TABLE ACTUAL DIG LINE MAY VARY, LOCATE STEEL 3" CLR FROM EARTH VERTICAL STEEL SEE TABLE HORIZONTAL STEEL #3 BARS @ 12" O.C. z 0 z 6" THICK ADDITIONAL BARS BEGIN AT 5'-0" FROM THE TOP OF POOL WALL (RAISED OR NOT RAISED) * IF POOL WALL HEIGHT DOES NOT EXCEED 5'-0", THEN NO BARS ARE REQUIRED. "-STRAIGHT WALL STANDARD WALL SECTION 7-IT-1I1 M• '111_ III IT1=1T1=11H - I1=1I1=1I1=1I I 1I-1I1=1I , 24" MIN. " EXTEND WALL RIENF. INTO FLOOR BRICK OR PRECAST CONCRETE COPING EXPANSION JOINT& SEALANT REQ'D. FOR EXPANSIVE SOILS DECKING— (3) #4 BARS E.F.P. 30 P.C.F. (4) #4 BARS 45 P.C.F. D R c VERTICAL C VERTICAL STEEL STEEL 3' 0" 1'-0" 3" #3 @ 12" 3" #3 @ 12" 3' 6" 1'-0" 3" 3" 4' 0" 1'-0" 3" 3" 4' 6" 1'-0" 3" 3>2" 5' 0" 1'-6" 3" #3 @ 6" 4" #3 @ 6" 5' 6" 2'-0" 3" 4" 6' 0" 2'-6" 3" 4" 6' 6" 3'-0" 3" 42" 7' 0" 3'-6" 3" 5" 7' 6" 4'-0" 3" 51,/2" 8' 0" 4'-6" 3" 6" 8' 6" 5' 0" 3" u 6" '-INDICATES TYPICAL RADIUS IS DISTANCE DOWN FROM TOP OF POOL WALL /-12'—/ -III III -III- III PLUMBING MAY BE LOCATED * , p` IN BOND BEAM LOWER CORNER. MAINTAIN 1" CLR. TO RIENF. 3" CLR.—i-- 3RD AND 4TH BAR LOCATION BAY VARY TO PROVIDE 2-1/2 " ,) CLR. BETWEEN PARALLEL BARS. TILE OND BEAM PER TABLE BOND BEAM HORIZONTAL BARS MAY BE OVER OR UNDER VERTICAL BARS Premier Pools and Spas LLC 439 E. Shore Dr. Suite 200 Eagle, ID. 83616 (208)-286-4988 www.ppas.com nJ W_OOZCO W J IzmOo 2Cn(°UW 7 � I cyO—< N J W N N Designer: SCOTT LAING Plans By: TODD ROWEY Date: 1 /23/2019 Revision Date: Revision Date: THIS PLAN IS PROPERTY OF PREMIER POOLS AND SPAS, LLC. ANY FORM OF DUPLICATION OR USE OF ALL OR ANY PLANS, DRAWINGS, OR DESIGNS IS PROHIBITED. COPYRIGHT 2018 STRUCTURAL DETAILS -111=111-1 11-111-11 1= 1 1 EI 1=1II 1 III 1=1l11d o , 111 11 1 (2) # 3 BARS BOND BEAM DETAIL